AKO PROPlus 3PH BASIC Guide Rapide page 23

Masquer les pouces Voir aussi pour PROPlus 3PH BASIC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.- Parameters
The parameters are grouped into 6 sections depending on their function. Press the N + Q keys for 10 seconds to
access it.
The Def. column shows factory-set default parameters.
Temperature values are expressed in ºC. (Equivalent temperature in ºF)
Level 1.- REGULATION AND CONTROL
SP Temperature Adjustment (Set Point)
C0 Calibrating probe 1 (Offset)
C1 Probe 1 differential (Histeresis) (Histéresis)
Upper blocking of the set point
C2
(cannot be set above this value)
Lower blocking of the set point
C3
(cannot be set below this value)
Type of delay for protection of the compressor
C4
0=OFF/ON (since the last disconnection);
1=OFF-ON/ON-OFF (since the last shut-down /start-up)
Protection delay time
C5
(value of the option selected in parameter C4)
Status of COMP. relay with probe fault :
0=OFF; 1=ON; 2=Average based on last 24 hours prior to probe fault;
C6
3=ON-OFF as prog. C7 and C8
Time relay ON in case of faulty probe:
C7
(If C7=0 and C8¹0, the relay will always be OFF deenergised)
Time relay OFF in case of fault of probe 1:
C8
(If C8=0 y C7¹0, the relay will always be ON energised)
Maximum duration of the continuous cycle mode.
C9
(0=disabled)
Variation of the set point (SP) in continuous cycle mode, when it reaches this point
(SP+C10), it reverts to the normal mode. (SP+C10 ³ C3)
C10
(0=OFF) The value of this parameter is always negative, except if it is 0
Idle time of the digital input for the change Set Point function to be activated
C11
(Only if P10 or P11 =1) (0=OFF)
Variation of the set point (SP) when the change set point function is active.
C12
(SP+C12 £ C2) (0= disabled)
EP Exit to Level 1
Description
23
1569H051 Ed.01
Units
Min
Def
Max.
(ºC/ºF)
-45
0.0
99
(ºC/ºF)
-20.0
0.0
20.0
(ºC/ºF)
0.1
2.0
20.0
(ºC/ºF)
C3
99
99
(ºC/ºF)
-45
-45
C2
0
0
(min.)
0
0
120
2
3
0
(min.)
0
10
120
(min.)
0
5
120
(h.)
0
0
48
(ºC/ºF)
0
-50
C3-SP
(h.)
0
0
24
(ºC/ºF)
C3-SP
0,0
C2-SP
1

Publicité

Table des Matières
loading

Table des Matières