Saci pumps DRENOX Série Manuel D'utilisation Et D'entretien page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
GB
®
DRENOX
range pumps have a built-in thermal overload with automatic reset.
Further protections are not required.
®
DRENOX
range three phase pumps can be protected by using a magneto-thermic motor protector or a contactor with thermal
relay; in both cases they have to be rated conforming to nominal power showed on motor plate.
Eventual electric float switch must be connected to auxiliary connector buckles.
Water head and delivery are terribly effected by wrong rotation of shaft of pump motor.
Clock wise rotation is correct ( upside view of pump ).
When starting the pump, motor will ungergo an anti-clock wise back-kick.
In this case test is positive; on contrary case, please disconnect pump from network and inverse two phases.
CONNECTIONS DIAGRAM:
1) START ( green )
2) RUN ( red )
3) COMMON ( black )
4) CAPACITOR
CHAP. 5 MAINTENANCE AND TROUBLE SHOOTING
No maintenance is required when DRENOX
Occasionally maintenance of liquid ends and replacement of impeller may be required.
FAULT
PUMP DOES NOT DELIVER,
MOTOR DOES NOT RUN.
PUMP DOES NOT DELIVER,
MOTOR RUNS.
PUMP DELIVERS REDUCED
WATER
INTERMITTENT WORKING
(SINGLE PHASE VERSION)
6
Overload Protection
Rotation direction testing three phase pumps
A) Single phase manual pump
B) Single phase automatic pump
C) Three phase pump
5) SUPPLY CORD
6) GROMMET
7) PLUG
8) YELLOW-GREEN
DANGER
Electric shock risk
DANGER
Electric shock risk
®
range pumps operate in normal conditions.
POSSIBLE CAUSE
1) No electric current supplying.
2) Incorrect plugging in .
3) Circuit-breaker come into operation.
4) Impeller blocked.
5) Motor or capacitor damaged.
1) Filter obstructed.
2) Non return valve blocked.
1) Filter partially obstructed .
2) Delivery pipe partially obstructed.
3) Impeller worn off.
4) Anticlockwise rotation ( three phase
version).
1) Solids obstruct impeller.
2) Too warm liquid.
3) Motor broken.
See diagrams Pict.2
9) WHITE
10) LIGHT BLUE < LINE >
11) BROWN < LINE >
12) FLOAT SWITCH
Before doing any operation, make sure pump is
disconnected from electric current network.
Power cord must be replaced by manufacturer or by
Customer service, using special tools.
REMEDY
2) Verify presence of electric current supply and
plug in.
3) Reinforce circuit-breaker.
Please call electrician in case circuit-breaker
comes again into operation.
4) Remove obstacle.
5) Call dealer.
1) Clean filter.
2) Clean or replace valve.
1) Clean filter.
2) Remove obstacles.
3) Replace impeller.
4) Inverse two phases.
1) Remove obstacles.
3) Call dealer.
See Pict. 2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Drenox 80/7Drenox 160/8Drenox 250/10Drenox 350/12

Table des Matières