1) Create the wireless bus
▶ Press the Connect button on module A once (the LED on module A will start flashing),
then press the Connect button on module B once (the connection between A and B is
established and the 2 modules stop flashing).
The two presses must occur within a maximum time of 30 seconds.
A
Led
Connect
1 press
▶ Repeat the same operation on modules B and C and so on, for all the others.
2) Pair the THERMARP thermostat with the module that controls the boiler
▶ After creating the wireless bus, temporarily move the thermostat to near the module
that controls the boiler. Pair the THERMARP thermostat with the module that controls
the boiler, following the steps described above.
3) Set the access point on the wireless bus
▶ Place the thermostat in its final position.
▶ Return to the Wireless menu
▶ Use the buttons
Access Point" submenu, then tap the "Confirm" icon
▶ Once the mode has been validated, the message
AP E7 starts flashing to confirm that the
THERMARP thermostat is in "Bus access point"
pairing mode. Press the "Connect" button of
the module closest to the THERMARP
thermostat once to establish the connection.
The PASS message appears briefly to confirm the connection.
DS1054-055A
B
Led
Connect
1 press
of the THERMARP thermostat.
to navigate the configuration menu to the AP E7 "Bus
and
.
Led
Connect
P18
C
Led
Connect
ETC
.