Malfunction - LK Armatur SmartBio LK 160 Manuel D'instruction

Masquer les pouces Voir aussi pour SmartBio LK 160:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
GB
ENGLISH
1.5.1 Anti-block pr...
Select
Anti-blocking
to prevent them from getting blocked. This func-
tion is not activated as long as the outputs are ac-
tivated in normal operation. Determine the time
of the day and the operating period. The pump
starts within 20 minutes of the set time. Press ESC.
Select
Antifreeze
1.5.3 Antifreeze pr...
If the function is activated and the temperature falls
below the adjusted
responding pump is switched on. If
sor
is activated in menu 0.7 it can also be used for
antifreeze protection. Press
toring.
Select
Pump
1.6 Monitoring
1.6.6 Pump moni-
To ensure the function of the pumps, fault criteria
to...
are defi ned here. Should temperature change
Temp. change1
reached within
will be shown. Press OK. Press ESC.
Select
Sensor
1.6.5 Sensor balan.... Long piping and other factors may distort measured
variables. Here an offset value can be entered for
each sensor. If a measured value is e.g. 80°C and the
display shows 85°C, the offset value is -5°C.
If a measures value is for e.g. 80°C and the display
shows 75°C, the offset value is +5°C. Press
twice. Select Login. Press OK.
1.7 Login
Select
1.7.1 Manual mode
In manual mode the individual outputs can be
activated for testing purposes, e.g. to check that
a pump is working properly. Manual mode can
only be exited by pressing ESC. The settings in
this menu are not saved.
If the professional mode is not exited actively, the SmartBio automatically displays
the selected hydraulic system after the display shut-off time and the value of the
login code is reset to 350.
The pumps can be run daily
protect.. Press OK.
Min.temperatur
value, the cor-
Tank bot. Sen-
ESC
twice. Select
monitoring. Press OK.
or
Temp. change2
not have been
Monitoring
time, an error message
balancing. Press OK.
Manual
mode. Press OK.

Malfunction

The screen on top right shows the red
points out a notifi cation or an operating malfunction. Press
1.10 Service Wizard
When
Safety function
Bio indicates that a protective function has been triggered.The mes-
sage is only active until normal operation has been restored.
SmartBio communicates malfunction processes in plain text. The
Moni-
Service Wizard indicates the possible causes of malfunctions on
the basis of the detected symptoms and thus supports immediate
detection of defi ciencies.
For example
MO2: Breakage of sensor on TS1
Press
.
OK
The Service Wizard helps detect possible causes of malfunctions.
Possible reasons: Cable/connection
pressing
. Select
OK
The Service Wizard provides the trouble-shooting instructions.
Press
to go through all check-points.
Next
Finally the repair information appears. Perform the appropriate
repair work. Press
After elimination of the malfunction, the plant screen without the
red attention triangle appears again on the display and automatic
ESC
mode is continued.
Attention
appears in the display, this is a message. Smart-
appears. Select
or
Sensor.
. Press
.
Exit
OK
to leave the Service Wizard.
Exit
triangle which
.
OK
.
Next
Select a cause by
9

Publicité