Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

The fitting must be installed, flushed and tested after
the valid norms.
Hansgrohe mixers can be used together with hydrau-
lically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:

English

Symbol description

max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Assembly see page 5
To adjust the hot water limiter on single lever
mixers, please see page 7. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Dimensions (see page 8)

Flow diagram

(see page 8)
with Eco
without Eco
Spare parts (see page 10)
Special accessories
special tool 580850009 (order as an extra)
Installation kit (order as an extra)
seal 98996000 (order as an extra)
Operation (see page 9)
Cleaning (see page 9) enclosed
brochure