Stud Discharge; Extended Front Sleeve; Contact Force Control; Foot Pedal - Honsel BZ 103 A Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 76

2 .7 .4 Stud discharge

The stud discharge can be used as an alternative
to a stud collector or stud securing cap. The stud
discharge is particularly suitable for workplaces
with large numbers of fasteners. With the stud
discharge, the sheared studs are discharged
through a hose into a separate container. Emptying
is not necessary and work can be continued
without interruption.

2 .7 .5 Extended front sleeve

The extended front sleeve allows a fastener to be
set in confined spaces. Extended front sleeves are
available in the lengths:
130 mm
170 mm
210 mm

2 .7 .6 Contact force control

The contact force control system is intended to
ensure that fasteners and parts are assembled
without gaps. The contact force control system also
has a safety function, as it prevents the tool being
triggered without a part.

2 .7 .7 Foot pedal

The foot pedal replaces the actuation of the trigger
by hand in order to have both hands free for
handling the part.

2 .7 .8 Axial trigger

The axial trigger allows a fastener to be set
vertically.
The nosepieces supplied with the
basis tool can no longer be used
after installation of the axial trigger.
The setting tool is supplied with
new nosepieces after fitting the
axial trigger.

2 .8 OPERATING MODES

ATTENTION
Improper extraction
Material damage
Do not use the extraction
system to pick up dirt or other
substances.
Use the extraction system only
as described in this manual.
On delivery, intermittent extraction
is set as operating mode.
36 | English

2 .8 .1 Intermittent extraction

In this operating mode, the extraction system is
activated when the trigger is pressed and runs for
approx. 2 to 3 seconds after the trigger is pressed.
This operating mode is suitable for use during
horizontal setting of a fastener with the fastener
inserted into the tool or with the fastener inserted
into the part. For this operating mode, a stud
collector must be screwed onto the setting tool or a
stud discharge tube attached.

2 .8 .2 Continuous extraction

In this operating mode, extraction is continuous.
This operating mode is recommended for all
applications where the fastener can easily fall
out of the nosepiece or out of the part before the
setting operation. The fastener is prevented from
falling out by the continuous extraction. For this
operating mode, a stud collector must be screwed
onto the setting tool or a stud discharge tube
attached.

2 .8 .3 Without extraction

No extraction takes place in this operating mode.
This operating mode is particularly suitable for
vertical setting of a fastener and for all applications
in confined spaces. For this operating mode, the
stud securing cap is screwed onto the setting tool
or a stud discharge tube is attached.

2 .9 GENERAL TECHNICAL DATA

Different configurations are possible
for each series by attaching
accessories / special options so
that the data may differ from those
specified for the basic tool.
Technical data
Weight in kg
Maximum tensile
force in kN
Stroke in mm
Application range
Protection class
Quality of the
compressed air used
Working pressure
Flow rate in l, min.
1.8
2.34
11.7 18.7 24.0 24.0
18
25
18
See Chapter 2.11
IP 44
Non-oiled
5 to 7 bar
2.4
3.5
3.5
3.5
18

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bz 133 aBz 123 aBz 143 a

Table des Matières