laguna PRESSURE-FLO 700 Mode D'emploi page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
Changing the UV-C lamp and Cleaning the Quartz Sleeve
Changing the UV-C lamp: to maintain optimum performance, the UV-C lamp (B)
should be replaced every year. An ideal time is Spring, during pre-season
pond maintenance.
Cleaning the Quartz Sleeve: although only filtered water passes through the UVC
section of the Pressure-Flo filter, the quartz sleeve (C) can become coated with
limescale, which will diminish the performance of the UV-C lamp (B). It is
recommended to check and clean the quartz sleeve (C) on a regular basis. The
frequency of cleaning depends on pond conditions.
In order to access the UV-C lamp (B) and the quartz sleeve (C), proceed as follows:
1) Switch off the UV-C lamp by disconnecting the unit plug from the main
power supply.
2) Switch off the pump that supplies the Pressure-Flo Filter.
3) Disconnect all hosing from the unit by releasing the click-fit couplings (push the
"press" button and pull).
4) Remove the UV-C head (A) (Fig. 5) from the filter by unscrewing the 4 screws (J)
that fasten the UV-C head to the filter lid (G).
5) At this stage it is possible to clean the quartz sleeve (C), if required.
Forcleaning the quartz sleeve, simply use a damp soft cloth. In case of
stubborn dirt, some vinegar may be used. Do not use detergents or
other chemical cleaners.
If it is not necessary to change the UV-C lamp, go straight to point #10.
J
Fig. 5
Y
D
B
F
C
E
K
6) To access the UV-C lamp (B), remove the Quartz Sleeve (C) by unscrewing the 2
screws (K) of the Retaining Flange (E) that fasten it to the UV-C head.
7) Pull out the UV-C lamp (B) away from the lamp holder (if it is not the first
start-up) and replace it with a new one. The Lamp holder pins must be correctly
oriented. If the Lamp does not fit at first, rotate it 90°.
WARNING - DO NOT ATTEMPT TO VIEW THE LAMP WHEN LIT!
Direct exposure to ultraviolet light can damage eyes and skin. Do not test
the UV-C lamp unless the filter is fully assembled and closed.
IMPORTANT – Use original Laguna spare parts only. Refer to the Spare Parts List
for correct part number identification.
8) Place the Quartz Sleeve (C) and the two O-rings (D) back in their original position.
IMPORTANT – The Lamp Damper (Y) inside the quartz sleeve must sit between
the lamp and the bottom of the quartz sleeve. Do not remove it.
IMPORTANT – The two O-rings (D) of the quartz sleeve (C) must be
replaced every time the unit is opened.
9) Place the retaining flange (E) in its original position and fasten it with the two
screws (K).
10) Check to ensure that the Quartz Sleeve (C) is not damaged. Check that all the
components are present and have been reassembled properly. If in doubt, consult
your Laguna dealer.
8
11) Put the UV-C head (A) back on the filter lid (G), ensuring that the inner O-ring (F)
is correctly located before securing the UV-C head with the screws (J).
12) Secure the UV-C head (A) to the filter lid, by refitting and tightening the 4 screws
(J). WARNING – Risk of Electric Shock: Before powering the lamp,
make sure that ALL O-Rings are back in their original position, ALL
screws are tightened and there has not been any damaged to the unit.
Before connecting the unit to the power supply, perform the Filter
Wet Test (see below).
13) The filter is now ready for start-up. Read and follow all instructions in
Filter Start-up, Operation, and Backwash-Cleaning.
Winter Storage
The unit must be protected from frost. In cold winter weather, the unit may be
switched off. It should then be drained of water, removed from its installation and
stored in a dry, weather-proof area. It is recommended to keep the unit lid open
during storage.
Filter Wet Test
Once the unit is fully assembled, it must be wet tested before connecting to the power
supply. This test must be repeated whenever the lamp and the quartz sleeve are
changed or disassembled.
1) Install the filter and connect it to the pump following all installation instructions. Do
NOT switch on the filter. Switch on the pump only and let it run for 24 hours.
2) After 24 hours, switch off the pump and remove the UV-C head (A) from filter by
unscrewing the 4 screws (J). Do not disassemble more parts.
3) Inspect inside the quartz sleeve (C) for leaks. If you see water inside the quartz
sleeve and around the lamp, do NOT connect the unit to power supply but take it to
an authorized Laguna service facility or similar qualified person for verification.
If on the contrary no water is visible inside the quartz sleeve (C), carefully reassemble
the unit and use it normally according to this Installation and Maintenance Guide.
A
Spare Parts
120V/60HZ
PF 700 UVC
PF 1400 UVC
PF 2100 UVC
230-240V/50HZ
PF 2500 UVC
PF 5000 UVC
PF 8000 UVC PF 12000 UVC
*
UV-C lamp
B
PT1520
PT1520
PT1521
+ 2 pcs O-rings
Quartz Sleeve
C
PT1524
PT1524
PT1525
+ 2 pcs O-rings
D
Quartz Sleeve
D
PT1527
PT1527
PT1527
O-rings (2 pcs)
Quartz Sleeve
E
PT1528
PT1528
PT1528
flange
UV-C Head O-ring
F
PT1530
PT1530
PT1530
Universal Click-fit
H
PT640
PT640
PT640
Sealing Cap Click-fit
I
PT1543
PT1543
PT1543
Head screws &
J
Quartz sleeve
PT1529
PT1529
PT1529
K
flange screws (6 pcs)
Foam cleaning
L
PT1513
PT1513
PT1514
blades (2 pcs)
Foam Filter(1 pc)
M
PT1510
PT1510
PT1511
Lid sealing O-ring
P
PT1535
PT1535
PT1536
Cleaning indicator
U
PT1538
PT1539
PT1540
(flange/indicator/spring)
Biospheres
PT1785
PT1785
Rubber O-Rings
aa
PT743
PT743
PT743
Instructions en français
Veuillez consulter les illustrations tout
en lisant le manuel d'instructions.
A Couvercle UV-C
B
Lampe UV-C
C
Manchon de quartz
D Bagues d'étanchéité
E
Bride de retenue du manchon de quartz
F
Bague d'étanchéité du couvercle de la lampe UV-C
G Couvercle du filtre
H Raccords universels autobloquants
I
Bouchon hermétique autobloquant
J
Vis du couvercle de la lampe UV-C
K Vis de la bride du manchon de quartz
L
Lames de nettoyage des blocs de mousse
M Bloc de mousse
N Support du bloc de mousse
O Manette de blocage du couvercle
P
Bague d'étanchéité du couvercle du filtre
Q Cuve du filtre
R
Témoin
S
Poignées de lavage
T
Orifice d'évacuation
U Indicateur de nettoyage
V Commande de sélection
W Sortie d'eau
X Entrée d'eau
PF 3200 UVC
Y Amortisseur de la lampe
Z
Tige métallique de sécurité
aa Bagues d'étanchéité en caoutchouc
PT1522
PT1526
PT1527
PT1528
PT1530
PT640
PT1543
PT1529
PT1514
PT1511
PT1536
U
PT1541
aa
PT1785
V
PT743
* See Product Illustrations
W
X
S
J
A
B
C
D
G
H
I
S
T
J
R
A
J
Y
E
K
F
L
M
N
O
Z
P
Q
9

Publicité

Table des Matières
loading

Table des Matières