Télécharger Imprimer la page

Auga VarioPress Pro 24000 Instructions D'utilisation page 38

Filtre à pression

Publicité

Les langues disponibles

Les langues disponibles

Cleaning quartz glass and replacing UV-C lamp and quartz glass
(illustration 8, 14 and 15, page 4, 6 and 7):
The UV-C lamp (4) has a life expectancy of about 7000 hours. If the lamp is used
24 hours a day, we recommend replacing it every season.
If the water turns green, clean the quartz glass first. If the UV-C lamp (4) has
taken 7000 service hours or when the water starts turning green again, the UV-C
lamp (4) needs to be replaced.
Observe the safety instructions.
1.
Unplug the UV-C and pump from the power outlet to turn them off.
WARNING! UV-C light is harmful to skin and eyes, always switch off the
UV-C lamp before replacing it.
2.
Remove the 4 screws from the UV-C cap (1).
3.
Lift the UV-C cap (1) straight up from the lid (8).
4.
Clean and dry the quartz glass (6) using clean pipe or pond water and a
soft, clean cloth, do not scratch.
If the UV-C lamp or quartz glass (6) don't need to be replaced, continue
with point 12.
5.
Loosen the quartz glass coupling nut (7).
6.
Carefully remove the quartz glass (6) from the UV-C cap (1).
7.
Inspect the quartz glass (6) for any cracks or damage, if necessary,
replace the quartz glass (6).
8.
Inspect the red seal (5) of the quartz glass, clean and replace the red
seal (5) if there are any signs of damage.
9.
If the UV-C lamp (4) needs to be replaced, remove it from the globe
fitting and replace with a new lamp.
Use the appropriate type of UV-C lamp, as indicated on the lamp or lamp
label. The wrong UV-C lamp will break and may cause damage
to other components of the pressure filter. Hold the new UV-C lamp with
a clean cloth.
10. Put the quarts glass back by pushing it in to the UV-C cap (1).
11. Tighten the coupling nut (7) of the quartz glass thoroughly.
12. Inspect the white seal (2) of the UV-C cap (1), clean and replace the
white seal (2) if there are any signs of damage.
13. Position the UV-C cap (1) straight up on the lid (8) and secure in place
with 2 hands.
14. Mount the 4 screws from the UV-C cap (1).
15. Put the pump into operation by plugging it into the power outlet. Follow
the pump instructions carefully.
16. If no leaking is found, you can also put the UV-C lamp of the pressure
filter into operation by plugging it into the power outlet.
English
www.auga.nl
38

Publicité

loading

Ce manuel est également adapté pour:

Variopress pro 40000Variopress pro 60000Variopress pro a