New System Parameters - RISCO Group WatchOUT eXtreme 315DT Guide D'installation

Détecteur extérieur à double technologie; modes relais et bus
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
Quick Keys
Parameter
[2][0][3][zzz]
MW Range options
[3][1]..[7]
1) Minimum
2) 20%
[2][0][3][zzz]
Anti-Mask sensitivity
[4]
Defines the sensitivity of the active IR AM
[2][0][3][zzz]
Anti-Mask sensitivity option
[4][1]..[2]
1) Low Sensitivity 2) High Sensitivity
[2][0][3][zzz]
Lens Type
[5]
Defines the actual Lens of the detector
[2][0][3][zzz]
Lens Type Options
[5][1]..[2]
1) Wide Angle 2) Barrier / Long Range
[2][0][3][zzz]
Anti-Mask
[6]
Defines the operation of Anti Masking detection
[2][0][3][zzz]
Anti-Mask Options
[6][1]..[2]
1) Disable 2) Enable (Default)
[2][0][3][zzz]
Arm/Disarm
[7]
Defines the operation of the LEDs anti masking detections while the detector
is armed
[2][0][3][zzz]
No
[7][1]
Active IR AM and Proximity AM (Anti masking) is enabled
LEDs behave according to the LEDs parameter definition
[2][0][3][zzz]
Yes
[7][2]
Active IR AM and Proximity AM (Anti masking) is disabled
LEDs are disabled
[2][0][3][zzz]
Proximity AM
[8]
Defines the operation of the Proximity Anti Masking detection
[2][0][3][zzz]
Proximity AM Options
[8][1]..[2]
1) Disable (Default) 2) Enable
NOTE: Disable Proximity AM during heavy rain (if WatchOUT 315DT is not
sheltered) to prevent Proximity AM alerts.
System Parameters
System: System Control
Quick Keys
Parameter
[1][2][36]
IR AM=Tamper
Used to determine the operation of Active IR Anti Masking detection
Yes: Active IR Anti mask detection will activate tamper alarm.
No: Active IR Anti mask detection will be regarded as trouble event.
[1][2][37]
Prox AM=Tamper
Used to determine the operation of the Proximity Anti Masking detection
Yes: Proximity Anti mask detection will activate tamper alarm.
No: Proximity Anti mask detection will be regarded as a trouble event.
16
3) 40%
5) 80%
4) 60%
6) Maximum
WatchOUT 315DT Installation Manual
Default
7) Trimmer (MW is defined
by the trimmer setting on
the PCB)
Low sensitivity
Wide Angle
Enable
No
Disable
Default:
No
No

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rokonet rk315dt

Table des Matières