Electrical Connections; General Information - Fulgor Milano 700 Série Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5 - Electrical Connections

EN
DANGER
Disconnect power before servicing the product. Failure to do
so could result in death or electrical shock.

General information

WARNING
The models may be powered at 240V or 208V.
This cooktop does not require a neutral connection. If the cooktop
is to be completely enclosed in a cabinet, feed the cooktop
cable through the opening in the cabinet. Make the electrical
connection following the appropriate steps for your installation.
Your cooktop must be connected to the proper electrical voltage and
frequency as specified in the table on the right.
Location of serial tag
Connect with copper wire only
If the house has aluminum wiring, follow the procedure below:
1. Connect the aluminum wiring to the copper wire by using
special connectors designed and Underwriters Laboratories-
listed for joining copper to aluminum. Follow the electrical
connector manufacturer's recommended procedure.
2. Aluminum/copper connection must conform with local
codes and industry- accepted wiring practices.
The flexible conduit (supplied) 3 feet long (100 cm)
located at the right rear of the cooktop bottom box should
be connected directly into a junction box. Do not cut the
conduit. A U.L - or CSA - listed conduit connector must
be provided at each end of the power supply cable (at
the cooktop and at the junction box.) A time delay fuse or
circuit breaker is recommended. Do not ground to a gas
pipe. Do not have a fuse in the grounding or neutral circuit.
Fuse both supply (phase) lines.
10
WARNING
Improper connection of aluminum house wiring to the copper
leads can result in a serious problem such as an electrical
fire.
Model
Power Supply
240 V 60 Hz
30" F7IT30*1
7,2kW 30A 6,45
36" F7IT36*1
10,8kW 45A 9,4kW 45A 815V50*U
National Fire Protection Association Batterymarch
Park, Quincy, Massachusetts 02169-7471
A three-wire, single phase, 240 Volt 60 cycle electrical system
(properly circuit protected to meet Local Codes of NFPA
No.70) must be provided. Unit must be properly grounded
in accordance with local wiring code. The chart below
recommends the minimum circuit protector and wire size if the
appliance is the only unit on the circuit. If smaller sizes of wire
are used, the unit efficiency will be reduced and a fire hazard
may be created. It is advisable that the electrical wiring and
hookup be accomplished by a competent electrician.
Recommended Minimum
kW Rating on
Circuit protection in
serial plate
amperes
0-4.8
4.9-6.9
7.0-9.9
10.0-11.9
12.0-14.9
Be sure your appliance is properly installed and grounded by a
qualified technician. Ask your dealer to recommend a qualified
technician or an authorized repair service. This cooktop does not
require a neutral connection. If the cooktop is to be completely
enclosed in a cabinet, feed the cooktop cable through the
opening in the cabinet. Make the electrical connection following
the appropriate steps for your installation.
Approval
208 V 60 Hz
code
31A 815T40*T
Wire size (AWG)
20
12
30
10
40
8
50
8
60
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F7it30s1F7it36s1

Table des Matières