DC Voltage
Range
400mV
4V
40V
400V
600V
Input Impedance:
Overload Protection: 600V DC/AC rms
AC Voltage
Range
4V
40V
400V
600V
Input Impedance:
Frequency Range:
Response:
Overload Protection: 600V DC/AC rms
DC Current
Range
400µA
4000µA
40mA
400mA
4A
10A
Overload Protection: Fuse 1 : F 400mA/690V - Fuse 2: F 10A/690V
Max. Input Current: 10A ( For inputs > 2A : measurement duration
Max. Measurement Voltage Drop: 400mV
Note: The 10A range is specified from 20% to 100% of range.
AC Current
Range
400µA
4000µA
40mA
400mA
4A
10A
Resolution
0.1mV
0.001V
0.01V
0.1V
1V
the range 400mV: >1000MΩ / the other ranges: 10MΩ
Resolution
0.001V
0.01V
0.1V
1V
10MΩ
40Hz -400Hz
Average, calibrated in rms of sine wave
Resolution
0.1µA
1µA
0.01mA
0.1mA
0.001A
0.01A
< 10 secs, interval > 15 minutes )
Resolution
0.1µA
1µA
0.01mA
0.1mA
0.001A
0.01A
18
Accuracy
± (1.0% + 5)
± (0.8% + 3)
± (1% + 5)
Accuracy
± (1.0% + 5)
± (1.2% + 5)
Accuracy
± (1.2% + 3)
± (1.5% + 3)
± (1.8% + 3)
± (2.0% + 5)
Accuracy
± (1.5% + 5)
± (1.8% + 5)
± (2.0% + 5)
± (2.5% + 10)