Permet d'automatiser la mise en marche et l'arrêt d'une électropompe, relatifs, respectivement, à la baisse de pression et à l'interruption du flux dans l'installation.
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
GB
3.
Operating pressure is pre-set at 1.5 bar which is the optimum
value for the majority of applications. Minimum operating pressure
can be adjusted as needed by turning the screw situated on the
side flange marked with + and -.
WARNING: TO ENSURE CORRECT WORKING OF THE FLUOMAC,
MAXIMUM PUMP PRESSURE MUST BE AT LEAST 0,6 BAR
HIGHER THAN FLUOMAC OPERATING PRESSURE.
4. STARTING FLUOMAC
WARNING: whenever the level of the priming water is lower than
the level of the water where the pump is placed, a suction line
equipped with an antibackflow foot valve is absolutely essential.
This valve allows the line to be filled when it is first used and
prevents it from being emptied when the pump stops.
1.
Before turning on, fill up the suction pipe and pump with water and
then start the pump by connecting the Fluomac power plug to a
current outlet; when the pump stops open the tap situated higher
up.
2.
Installation is correct if the flow from the tap is regular and if the
pump works continuously. If there is no water you can try to make
the pump work without interruption - for a period of time longer
than the device's working time - by keeping the RESET button
depressed. If the problem persists, disconnect the Fluomac and
repeat the procedure from point 1.
Dry stop: The red FAILURE LED lits up with motor off to indicate a
dry stop. To start the system again press the RESET button after
having checked the presence of water in the suction pipe.