GEMINI
GEMINI can be used with Powerpak,
TORNADO
or
respirator systems provided that the
correct filter type is fitted.
In such cases, ensure that this manual is
read in conjunction with the following
publications:
Product
Publication
User Manual
Powerpak
Filter Manual
User Manual
Tornado
Filter Manual
User Manual
Proflow
Filter Manual
Please contact our Customer Services
Department if you require any further
information.
GEMINI is easily dismantled for repair
and servicing. However, please note that
servicing should only be carried out by
trained, authorised personnel.
FILTERS
The following filters are available for use
with GEMINI:
Code
Filter Type
EC200R
A2
EC201R
B2
EC203R
K2
EC213R
ABEK2
EC219R
AX
EC220R
A2 P3
EC221R
B2 P3
EC222R
E2 P3
EC223R
K2 P3
EC230R
A2 B2 E1 P3
EC233R
ABEK2 P3
EC238R
AE1Hg P3
EC239R
AXP3
EC251R
P3
Proflow
powered
Article No.
1065558
1064883
1070613
1070782
009741
009752
Standard
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 143 : 2000
WEARING
1.
Ensure that the facemask is clean
and
undamaged,
attention to the inhale and exhale valves;
and head harness.
2.
Ensure that the inhale valve frame
is present, in good condition and correctly
seated in the front fitting. Replace if
necessary.
3.
Check that the filter intended for
use is not clogged, saturated or time-
expired and is suitable for the hazards
that may be encountered. Fit a new filter if
necessary.
4.
Ensure that the filter is securely
fitted to the mask.
5.
Ensure that the visor is clear and
free from scratches or other abrasions
which could impair vision.
6.
Hang the mask around your neck
by the neckstrap, fully slacken the head
harness and remove the filter cover.
7.
Hold the head harness with the
thumbs inside the harness. Fit the chin
into the chin-cup and pull the harness
over the head. Gently tighten the harness
straps; lower first, then middle and finally
the top strap. A good seal should be
achieved without over-tightening, which
will distort the faceseal and cause
discomfort to the wearer.
8.
Check the mask seal to the face by
covering the filter inlet with a hand or the
filter blanking cover and inhaling. The
mask should pull onto the face. Hold your
breath for 10 seconds and check that the
mask seal is maintained over the 10
second period. If the seal fails, indicated
by the mask pulling away from the face,
check that the filter is properly fitted and
adjust the mask seal to the face, then
repeat the test. If it fails a second time,
the mask should be serviced.
WARNING:
If the mask does not seal correctly
after servicing, DO NOT use.