TX Series Owners Manual
Chlorine damage to membranes
System Not Consistently Running
Low pressure
Filter cartridge
System leak
Low permeate flow
Membranes fouled
Float switch not operating properly
Poor Production Volume
System not operating within specifications
Cold temperature
Fouled membranes
Low pump pressure
Inlet quality changes
Kinetico Incorporated  Corporate Headquarters  Newbury, Ohio 44065  440-564-9111
Rev. 11/2016
Check inlet chlorine levels, residual less than 0.05 mg/L is
required to prevent thin film composite membrane
deterioration.
Feed pressure too low. Check inlet PSI while system is
running. System will shutdown if feed psi is below 15 psi
(1.0 bar).
Replace if pressure loss exceeds 5 psi.
Check and repair.
Water temperature is low.
Membranes are fouled.
Check system log for history. If consistent declining
production is found, clean membranes. Consult your
Kinetico dealer for appropriate cleaning procedures and
chemicals.
Confirm system operating parameters.
Check operation of high level switch.
Confirm system operating parameters. System should run at
provided permeate, recycle and reject flow rates.
Inlet temperature less than 77
Check permeate quality.
The TX RO systems are designed to permeate projected
volumes at a pump pressure of 110 psi and a temperature at
o
least 77
F. Check if pump pressure yields less than 110
psi.
Analyze RO feed for chlorine, hardness and temperature.
21
o
F.