Télécharger Imprimer la page

Avidsen ORANE400 Guide De Démarrage Rapide page 2

Masquer les pouces Voir aussi pour ORANE400:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Articulated arm gate opener kit
For swing gates
QUICK START GUIDE
≤200kg
≤200kg
≤2,5m ≤2,5m
24V
option
Thank you for purchasing an AVIDSEN automatic gate opener.
This document is a quick start guide detailing the main installation steps as well as the equipment required. To perform the installation,
please download the installation manual at the following address: www.avidsen.com/produits/recherche.php
Warning: The safety instructions and installation instructions can be found in the installation manual. Follow all these instructions, as an
incorrect installation can cause serious injuries.
CONTENTS OF THE KIT
1
1
3
x 1
x 1
x 2
8
x 2
9
x 2
10
x 2
11
x 2
12
x 4
1
Left motor with integrated electronics
7
Front right arm
2
Right motor
8
Pillar mounting bracket
3
Remote control
9
Gate mounting bracket
4
Flashing light
10
M12 CHC – L50 screw
5
Rear arm
11
M12 CHC – L40 screw
6
Front left arm
12
M8 – L80 screw
13
M8 – L15 screw
EQUIPMENT REQUIRED (NOT SUPPLIED)
The tools and screws required for the installation must be in good condition and compliant with applicable safety standards.
1 fl at head screwdriver
1 drill
1 Phillips screwdriver
1 spirit level
fl ashing light
right motor
Choosing a system
screws / nuts suitable
the thickness of the
gate. There are 4
3m cable
8m cable
2 x 0.5mm2
2 x 1.5mm2
ORANE400
Reference: 114156
4
5
6
x 1
x 2
x 1
13
x 2
14
x 2
15
x 4
16
x 4
17
x 4
14
D27-9-2 washer
15
M12 nut
16
M8 nut
17
D20-12-2 nylon washer
18
D20-12-1 nylon washer
19
Allen key
20
Spring washer
1 pencil
1 x 13mm spanner
1 x 19mm box span-
1 measuring
ner and 1 x 13mm
tape
box spanner
1 x 3mm Allen key
fi xing lugs
attachment of the
attachment of the
on the portal:
fl ashing light onto the
motors
pillar
onto the pillars
mounting points
INSTALLATION
Safety guidelines: please refer to the installation manual for all safety instructions.
To perform the installation, please download the installation manual at the following address: www.avidsen.com/produits/recherche.php
V3
Overview:
The cables used must be appropriate for outdoor use (such as H07RN-F for example).
The cable run between the two pillars must comply with applicable standards (NFC 15-100).
The geared motor power cable must run 80cm deep with red warning mesh.
Flashing light
2
1
List of cables:
Connection
1
230Vac power line
7
x 1
2
Flashing light
3
Right motor
The installation is a 4-step process:
1. Installation of the motors onto the pillars and gate, and of the fl ashing light.
2. Electrical connection:
- of the right motor to the electronic card (in the left motor)
- of the fl ashing light to the electronic card (in the left motor)
- of the left motor to the mains. This connection must be performed by qualifi ed personnel (electrician, etc.)
18
x 2
3. Adjustments and operation:
Warning: Only switch on the system once all connections have been made.
- Read the installation manual chapter on simple adjustments.
- Launch the movement self-learning programme (press "+" for 3 seconds)
- Programme the remote controls:
- press "-" for 3 seconds
19
x 1
- press "OK"
- press the remote control button to be memorised
- Repeat the operation for each remote control
- Choice of operating mode:
By default, automatic closing is deactivated. To activate it:
20
x 2
- Press "PROG" for 3 seconds
- Press "OK"
- Press "+"
- Press "OK"
4. Operational testing: To familiarise yourself with the automatism and ensure its proper operation, read the chapter on usage and conduct operational tests (opening/closing,
initiate obstacle detection, cut the photocell beam (optional). Upon completion of these tests, you may have to modify certain settings (e.g. motor power).
DECLARATION OF CONFORMITY
With the R&TTE directive AVIDSEN declares that the following equipment: ORANE400 articulated arm gate opener kit reference 114156
Complies with the R&TTE 99/5/EC directive. Its conformity has been assessed pursuant to the applicable standards in force:
• EN 301489-3 V1.6.1
• EN 301489-1 V1.9.2
• EN 300220-1 V2.4.1
• EN 300220-2 V2.4.1
• EN 55014-2 :1997+A1 :2001+A2 :2008
• EN 55014-1 :2005+A1 :2009+A2 :2011
• EN 61000-3-2 :2014
• EN 61000-3-3 :2013
• EN 60335-1 :2012
• EN 60335-2-103 :2003 + A11 :2009
The remote control included with the abovementioned product complies with the R&TTE 99/5/EC directive. Its conformity has been assessed pursuant to the applicable standards
in force:
• EN 301489-3 V1.6.1
• EN 301489-1 V1.9.2
• EN 300220-1 V2.4.1
• EN 300220-2 V2.4.1
• EN 60950-1 :2006 + A11 :2009+A1 :2010+A2 :2013
motors
3
Inner side of the property
Cable
Max length
Cable 3 x 2.5mm2 (more than 30m long)
Unlimited
Cable 3 x 1.5mm2 (less than 30m long)
Cable 2 x 0.5mm2
15m
Cable 2 x 1.5mm²
10m
Chambray les Tours, date: 20/12/15
Alexandre Chaverot, CEO

Publicité

loading

Ce manuel est également adapté pour:

114156