Hansgrohe Crometta E 240 1jet Showerpipe EcoSmart Mode D'emploi Et Notice De Montage page 4

Masquer les pouces Voir aussi pour Crometta E 240 1jet Showerpipe EcoSmart:
Table des Matières

Publicité

Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
The product may only be used for bathing, hygienic and body cleaning pur-
poses.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• During installation of the product by qualified trained personnel, make sure that
the entire fastening surface is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the product and has no weak
points.
• The mesh washer must be insert to protect the shower against incoming dirt
by pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• The product is not designed to be used with steam baths!
• If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
• In case of problems with the continuous water heater or of greatly varying water
pressures, you must install the water limiter (comprised in the delivery, article
number 97510000) in the cold water supply.
Technical Data
Operating pressure:
27268000 Recommended operating pressure:
27281000 Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
Thermal disinfection:
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Instantaneous heater didn't work with thermostat
4
English
max. 1 MPa
0,1 - 0,5 MPa
0,13 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
150 ±12 mm
cold right - hot left
max. 70°C / 4 min
Cause
- Supply pressure inadequate
- Filters are dirty #96922000
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't removed
Assembly see page
Safety against backflow
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function
The desired maximum temperature for example max. 42º C can be
pre-set thanks to the safety function.
Adjustment
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Maintenance
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
Dimensions
Flow diagram
Hand shower
overhead shower
Operation
To empty the overhead shower after use, hold it in a slightly
inclined position.
Cleaning
Spare parts
Special accessories (order as an extra)
tile-matching-disk chrome plated #95239000
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Crometta s 240 1jet showerpipe ecosmart2728100027268000

Table des Matières