Master /Slave Mode; Operation; Dmx Control; Operation Without Dmx Controller - Monacor International IMG STAGELINE XBEAM-410LED Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.2 Master /slave mode

Synchronous operation of multiple XBEAM-410LED
spotlights with the same show program is also
possible without a DMX controller . The first unit
(master) will control the other units (slaves) . Con-
nect the units in a chain according to chapter 5 .1;
however, do not connect the DMX input of the
master unit (fig . 5) .

6 Operation

WARNING To prevent damage to your eyes,
never look directly into the light
source for any length of time .
Please note that stroboscope ef-
fects and fast changes in lighting
may trigger epileptic seizures with
photosensitive persons or persons
with epilepsy!
Connect the mains cable provided to the mains
jack (6) first, and then connect it to a socket
(230 V/ 50 Hz) . The unit is switched on: After a reset
(reset of the motor control), the unit will return to
its previous operating mode . The indication on the
display (3) will disappear a few seconds after the
unit has been set into operation .
The settings are made via a menu using the control
buttons (2) (refer to chapter 8) . The display indi-
cation will appear when a button is pressed and
disappear after a few seconds when no button is
pressed .
Button
Functions
– to return to the previous menu level;
when the button is pressed while a
MENU
menu item of the highest menu level is
displayed, the unit will go to the menu
item "DMX start address"
– to navigate through the menu
UP and
DOWN
– to change a value or to select a setting
– to call up a menu item / submenu
ENTER
– to confirm and save a setting at the same
time
Master unit
DMX
output
Master/slave mode
12
Slave unit
Slave unit
DMX
DMX
DMX
input
output
input

6.1 DMX control

For operation with a DMX controller, set the num-
ber of channels and the DMX start address:
1) Set the number of channels (7 or 14 channels)
via the menu item
channels depends on the functions required
(refer to the table in chapter 8) and may also
depend on the number of control channels avail-
able on the controller .
2) Set the DMX start address via the menu item
. For separate control of all DMX-controlled
units, each unit must have its own start address .
Example: If the first DMX channel of the unit is
to be controlled by the light controller via DMX
address 5, set the start address on the unit to 5 .
All other DMX channels of the unit will be auto-
matically assigned to the subsequent addresses .
Example: In the 7-channel mode with start address 5,
the channels 1 to 7 are assigned to the addresses 5
to 11 . Address 12 is the next possible start address
available for the following DMX-controlled unit .
When the number of channels and the start ad-
dress have been set, the unit can be operated via
the DMX controller . A dot keeps permanently flash-
ing on the display to indicate that the unit is in the
"DMX control" mode and that a DMX signal is
available at the DMX input .
When a DMX signal is applied, the unit will not
automatically go to "DMX control" . To go to "DMX
control" from a different operating mode, call up
the menu item for the start address or the number
of channels and confirm the setting .

6.2 Operation without DMX controller

6.2.1 Show programs 1 to 8

To start an automatic show program, select the
desired program via the menu item
confirm .
If the music-controlled program is still running,
deactivate the music control first (set menu item
to
Slave unit
DMX
DMX
DMX
output
input
output
. The number of DMX
) .
Slave unit
DMX
input
and
DMX
output
DMX terminating plug
(if required)

Publicité

Table des Matières
loading

Table des Matières