Technical Specification - HYGIPLAS J242 Mode D'emploi

Masquer les pouces Voir aussi pour J242:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
Telephone Helpline: 0845 146 2887 (United Kingdom)
Rotary Probe Pocket Thermometer
UK
Safety Tips
Clean the probe immediately after each measurement to avoid cross contamination.
Do not expose the appliance to temperatures over 50ºC/122ºF or use in ovens.
Installation
1.
Open the battery compartment on the bottom of the appliance.
2.
Insert the battery (Negative (-) terminal first).
3.
Close the battery cover.
Operation
Temperature Measurement
1.
Press the On/Off button to power up the thermometer.
2.
Open up the probe to the desired angle.
3.
Insert the probe approximately 25mm (1") into the foodstuff.
4.
The temperature of the foodstuff is displayed when the value remains constant.
Units of Measurement
1.
Press the ºC/ºF button to alternate between Centigrade and Fahrenheit.
Data Hold
1.
Press the HOLD button to keep the current reading displayed.
2.
Press the HOLD button again to resume normal operation.
Maximum/Minimum Readings
The thermometer can store and display the maximum and minimum temperature readings taken since
the last reset:
1.
Press the MAX/MIN button. The MAX icon flashes and the maximum temperature taken displays
on the screen.
2.
Press the MAX/MIN button again. The MIN icon flashes and the minimum temperature taken
displays on the screen.
3.
Press the button again to resume normal operation.
Note: To reset the memory press and hold the MAX/MIN button for 3 seconds.
Always reset the memory before taking new readings to ensure accurate
readings.
Low Battery Warning
Replace the battery when the low battery icon (

Technical Specification

Temperature range
Temperature reading accuracy
Resolution
Temperature display refresh rate
Display size
Battery
Probe size
Thermometer dimensions (hxwxd)
Ambient operating temperature
Troubleshooting
If the appliance ceases to function correctly, press and hold the red RESET button (situated on the
back of the appliance) using a pointed instrument.
All rights reserved. No part of these instructions may be produced or transmitted in any form
or by any means, electronic, mechanical, photocopying, recording or otherwise, without the
Every effort is made to ensure all details are correct at the time of going to press, however,
HYGIPLAS reserve the right to change specifications without notice.
-50-300ºC/-58-572ºF
± 2ºC/3.6ºF between -50~-20ºC/-58~-4ºF
± 1ºC/1.8ºF between -20~150ºC/-4~-302ºF
± 3ºC/5.4ºF between 150~250ºC/302~482ºF
± 4ºC/7.2ºF between 250~300ºC/482~572ºF
0.1ºC over full range
1 second
16(h) x 28(w) mm
1 x AAA 1.5v
3.5(Ø) x 115(l) mm
160 x 52 x 21 mm
0-50ºC / 32-122ºF
prior written permission of HYGIPLAS.
1
) appears on the display.

Publicité

Table des Matières
loading

Table des Matières