Controls; Positioning The Accessories And Pipe; Start-Up And Operation; Filter Shaker - FIORENTINI K73F1-D Mode D'emploi

Aspirateur destiné à un usage commercial ou domestique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3 Controls

3.1 Positioning the accessories and pipe*

The machine is equipped, on the trolley base, with
a removable accessory holder in which you can
insert the accessories supplied and place the rigid
part of the vacuum pipe, resting on the trolley
handle.

3.2 Start-up and operation

Check that the electric switch is disabled (position
0).
Check that special filters are installed in the
appliance. Then, connect the vacuum hose by
inserting it into the appliance's vacuum nozzle,
pushing the pipe forwards until it clicks firmly into
place in the nozzle. Connect the accessory to the
hose, twisting them to make sure that they are
mounted properly. Choose the suitable accessory
according to the type of material to be vacuumed.
Connect the plug to a suitable power socket. Push
the power socket to position I to start the motor.

3.3 Filter shaker*

The appliance is equipped with a semi-automatic
filter cleaning system. The filter cleaning system
must be used when the vacuum power is no longer
enough. Regular use of the filter cleaning function
increases the duration of the filter.
With the machine switched on, cover the nozzle
opening or vacuum pipe with the palm of your
hand.
Press the button shown in the figure quickly at
least three times. This way pressure waves are
generated within the filter that ensure the
*Optional feature depending on the model.
detachment of the vacuumed material from the
outer filter surface.
Due to the pressure inside the machine, you must
press the filter shaker button firmly. This is not a
malfunction and the internal parts of the
mechanism are sized to withstand such pressure.

3.4 Socket for power tool*

The appliance can be equipped with the
synchronous power tool socket function.
Switch the vacuum cleaner and power tool off.
Connect the electric plug of the power tool to the
socket on the vacuum cleaner head.
Connect the power tool dust outlet to the
appliance's vacuum pipe, using the special
adapter.
Switch the appliance on with switch on position II
or on the power tool symbol.
Switch the power tool on. The vacuum motor starts
when the connected electrical device is switched
on.
After the electrical appliance has been switched
off, the vacuum cleaner will continue to operate for
a short time, so that the dust which is still in the
vacuum pipe is conveyed into the collection drum.
The vacuum cleaner is switched on and off via the
connected electrical device. Dirt is absorbed
directly in the dust formation point.
EN
5

Publicité

Table des Matières
loading

Table des Matières