Control Elements - Unitest 8986 Mode D'emploi

Controleur de terre
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.0 Control Elements

Indications in Display
(Also refer to display indications in chapter 7.0):
1) Warning symbol...
2) Limit:/Probe/Unoise
3) Battery condition indication
4) Indication of units (depending on the selection
made (8)) for V, kW, mA
5) Frequency indication
f1=127Hz/ f2=140Hz
6) Automatic/manual frequency selection
7) Contact voltage
8) Measurement variable indication (only in Ger-
man version !)
Control Elements
9) Connecting sockets for test leads:
auxiliary ground...(H)........
probe...................(S).........
ground probe ......(ES).......
ground.................(E).........
10) LC Display
11) Key for contact voltage:..
50V/ 25V (25V for medical and
agricultural applications )
12) Key for manual frequency:........
f1=127Hz/ f2=140Hz
13) Measurement method selection switch:
Off, 4pole, 3pole, 2pole measurement
14) Start key
15) Battery case instrument rear
16) Key for automatic/
manual frequency selection:..
17) Selection key for measurement variable
indication (8) in display:
RE - grounding resistance
RH - auxiliary ground resistance
RS - probe resistance
Im - measurement current
black
yellow
red
blue
17
16
Control Elements
9
10
11
12
13
14
15
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Telaris erde

Table des Matières