Velleman CU2200 Notice D'emploi page 9

Masquer les pouces Voir aussi pour CU2200:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Example 2:
PWD:1234,ALMLEVEL1:1,11,1230,100#%
Password
Alarm channel 2
• SMS Alarm Message Setup
Alarm channel 1 ~ 8
Command: PWD:XXXX,ALMYTEXT:□□□□□□□□□□□□#%
XXXX
Password
Y
Alarm channel number (1 ~ 8)
SMS message (max. 100 characters – no space allowed)
□□□□□□□□
Example:
PWD:1234,ALM4TEXT:DoorContact1Open#%
Password
Alarm channel 4 is triggered, SMS message Door Contact 1 Open is sent to
the pre-defined phone numbers.
A/D channel 1 ~ 2
Command: PWD:XXXX,ACHYTEXT:□□□□□□□□□□□□#%
XXXX
Password
Y
A/D channel number (1 ~ 2)
SMS message (max. 100 characters – no space allowed)
□□□□□□□□
Example:
PWD:1234,ACH2TEXT:HighTemperatureAlert#%
Threshold high
A/D value
Password
Date
Time
A/D channel captured is higher than threshold high, so alert SMS is sent with
following message content:
HighTemperatureAlert ST:001;TM:200706121923;A2:5.123#
CU2200_v4
1234
Once the input is closed, the alarm will be triggered
Control centre 1 and 2 will be reported by SMS
Phone number 1
Phone number 2
Phone number 3
Phone number 4
Relay output 1
Relay output 2
Relay output 3
1234
4.250
5.123
1234
2007-06-12
19:23
SMS message
Phone dial
SMS message, then phone dial
No report
Triggered
No control (not available)
No control (not available)
9
VELLEMAN

Publicité

Table des Matières
loading

Table des Matières