The spring of the snap hook (31) and of the hook (17) must be in perfect condition and the safeguard must lock properly.
Check the complete cable:
in case of damages A
fracture of a few or single wire), B or C (fracture of a
(
wire strand) the cable has to be replaced immediately (Figure i).
Maintenance on the installed balancer:
grease the cable (14) and the button (1);
use cable grease BEACON 320 (ESSO) or similar.

6 Maintenance of the balancer

Before taking of the load, retract completely the cable (14) (buffer (28) on the guiding rail (27)): an extracted cable with
stressed spring should resile very quickly and cause personal injury and material damages.
Take off the balancer very carefully from the support.
The spring/drum unit (13) must be completely released before the intervention.
Two possibilities to check this:
1. smooth rotation of the drum through the cable (14), by lifting the pin (4) (figure d).
2. approx. 4 mm protruding of the screw (45) (figure g).
Disassembling of the balancer
Take off the retaining ring (22), the screw (40); take off the housing (5); completely unwind the cable (14); take off the axle
(11) eventually by the means of a plastic hammer.
Check the spring/drum unit (13): if the internal spring has been damaged, the complete cable guide has to be replaced.
The spring/drum unit (13) is sealed and greased before delivery and ball bearings are included: never open it!
Check the cable (14); if damages like A, B or C are detected, it has to be replaced immediately (figure i).
The centrifuge mass of the disk (9) must swing freely; the springs (37) must be OK and guaranty the return of the centrifuge
mass; check the housing (5) (figure e).
The disk of the safety centrifuge (9) is a complete unite. Only the springs (37) are spare parts.
Check all the sealings (8 and 38). The screw (45) and the bolt (43) must run and turn in axial direction; check the springs (6
and 42).
Mounting of the balancer:
Check the swinging of the lock (A).
20 Nm adjustment of the screw (15) on the cable clamp (14).
Grease the cable and wind it exactly into the spring/drum unit (13). Make sure that the cable is lying in the lock (A), then install
it.
5 Nm adjustment of the screw (39) of the safety disk (9).
BAL0400-0019b-D/E/F
www.conductix.com