tau D704M Notice D'installation page 14

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. LOGIC ADJUSTMENTS
TRIMMER
T.L.
Work Time adjustment: from approx. 5 to 240 seconds;
T.C.A.
Automatic Closing Time adjustment: from approx. 5 to 120 seconds (see dip switch 1);
FR.
obstacle detection sensitivity adjustment.
N.B.:
turn the TRIMMER clockwise to increase adjustments; turn it anticlockwise to decrease.
Dip switches
1
on: after opening, the gate automatically closes when the delay set on the T.C.A. trimmer expires;
off: a command is required to close the gate;
2
on: with automatic closing enabled, a sequence of open/close commands causes the gate to
OPEN-CLOSE-OPEN-CLOSE etc.;
off: in the same conditions, the same command sequence causes the gate to OPEN-STOP-CLOSE-
STOP-OPEN-STOP (step-by-step) (see also dip switch 9);
3
on: Man Present; the automation system will continue to open or close as long as the OPEN or
CLOSE buttons are held down. The gear motor will stop when the button is released;
off: normal (or pulse); when the OPEN, CLOSE or the PP button is pushed, the automatic system
performs a complete opening or closing manoeuvre;
N.B.
In the Man Present mode, the PP input (n° 12) is disabled, as is the radio receiver.
4
on: braking disabled;
5
on: encoder disabled;
6
on: pre-flashing and "photocell test" function enabled;
off: pre-flashing and "photocell test" function disabled;
7
on: after the photocell contact triggers (input 13 - 16), the automation system closes after 5 seconds;
off: function disabled;
8
on: the gate works as set by dip switch 2
off: the gate ignores the close command during the opening cycle;
9
on: during opening, the photocell cuts in to stop the gate until the obstacle is removed. During
closing, it stops the gate and then totally reopens it.
off: during opening, the photocell does not trigger while during closing, it behaves as if the dip
switch were on;
10 on: right-hand leaf opening function;
N.B.
Operate dip-switch No. 10 HAVING PREVIOUSLY turned off the power supply .
N.B.
The braking system activates whenever the motor must stop (FCC - FCA - STOP – change
of direction) and reduces the inertia accumulated by the gear motor during movement.
Clock function:
A timer can be connected to the open-close pushbutton in order to keep the gate open at certain
times during the day, after which it reverts to automatic closing.
TL
-
+
-
off: braking enabled;
off: encoder enabled;
TCA
FR
+
-
+
off: left-hand leaf opening function;
TL
TCA
-
+
-
+
-
ON
1
2
3
4
5
6
7
8
9
14
Dip-switches
CN1
FR
+
10