Klimasan S 56 SC Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. ASSEMBLING SINGLE DOOR VISI-COOLERS / THE INITIAL START UP
Air circulation at the rear is required for the visi/coolers operate efficiently.
Move the visi/cooler backwards to place it properly.
Allow minimum 5cm of space from the sides and the rear in order to ensure proper air
circulation. Leave the top of the visi/cooler free.
For models S 88 SC and S 56 SC, allow minimum 5 cm of space from the rear and minimum
30 cm of space from the sides for proper air circulation.
Your visi/cooler is now ready to plug in.
6. OPERATING SINGLE DOOR VISI-COOLERS
Avoid blocking air circulation inside the visi-cooler, when loading the visi/cooler with food
products. Otherwise undesired and extensive temperature variances may occur between the top
and bottom compartments of the visi/cooler.
Control Panel:
Control panel consists of the following components depending on the model:
Green Light:
It is lit so long as the visi-cooler is connected to the electric supply.( D 372SCM3)
Thermostat Setting Knob:
It is used to regulate the internal temperature of your visi/cooler.
Thermostat setting must be done according to the features of the products to be preserved.
Temperature setting can be done by means of turning the black thermostat knob on the control
panel by the help of a coin or similar object. Turning the knob right decreases the internal
temperature, whereas turning it left increases the internal temperature.
Turning the knob
leftmost stops the compressor, which in turn stops the chilling process, although the electric
current to the visi/cooler is not cut off.
Location of the thermostat-setting knob depends on the visi/cooler model. In Models D418GCD,
D418GCD C and D149SC the knob is installed on the internal ventilation fan panel inside the
body while it is installed on the left upper corner on the rear in Model S 88 SC or S 56 SC.
Internal Ventilation Fan Switch:
It used to provide air circulation inside the visi-cooler. (D 372SCM3- S88 SC-D418GCD/C)
Internal Lighting Switch:
It is used to turn on or off the internal light of your visi-cooler. If the light bulb does not
function anymore, always unplug the visi-cooler from the mains before replacing it. Pull up
the lamp cover. Rotate the electric bulb 90 degrees, take it off and replace it with a new
one. Always replace the starter whenever you replace the electric bulb. (D 372 SCM3/3C)
7

Publicité

Table des Matières
loading

Table des Matières