Booster Heater Sizing Chart

Use the table below or the "Booster Heater Sizing Formula" to determine what Booster Heater kW rating is needed with your
dishmachine.
1. Determine the water temperature rise.
a. Subtract the lowest incoming water temperature supplied to the Booster Heater from the desired output water temperature
of the Booster Heater. The difference is the Water Temperature Rise. Typically 145°F (63°C) is a low temperature chemical
sanitizing application and 185°F (85°C) is a high temperature heated water sanitizing application.
2. Follow the appropriate "Water Temperature Rise" column down and locate the Gallons Per Hour (GPH) of the dishmachine's rinse
cycle (round up to the next size if exact GPH isn't listed).
NOTE: The primary water heater must be able to supply the Booster Heater with the incoming water temperature at the GPH usage
of the dishmachine. Failure of the primary water heater to supply a continuous temperature will result in an inadequate
output temperature of the Booster Heater.
3. Follow the GPH row to either of the "Booster Heater kW" columns for the appropriate Booster Heater kW rating.
Example: An incoming water temperature of 115°F (46°C) with a desired output temperature of 185°F (85°C) would be a 70°F
(39°C) water temperature rise.
A 70°F (39°C) water temperature rise with a dishmachine capable of 185 GPH usage will require a minimum of a 36 kW
Booster Heater.
NOTE: When incoming water temperatures are less than 85°F (29°C), consult factory for suitable Booster Heater.
Booster
30°F
Heater
kW
GPH
4
54
5
67
6
80
7
94
9
120
9.9
132
10.5
140
11.4
153
12
161
13.5
181
15
201
17.25
231
18
241
24
321
27
361
30
401
36
482
39
522
40.5
542
45
602
54
723
57
763
Booster Heater Sizing Formula
LPH x Water Temp. Rise
840
Water Temperature Rise
40°F
50°F
GPH
GPH
40
32
50
40
60
48
70
56
90
72
99
79
105
84
114
92
120
96
135
108
151
120
173
139
181
145
241
193
271
217
301
241
361
289
391
313
407
325
452
361
542
434
573
458
= kW
60°F
70°F
GPH
GPH
27
23
33
29
40
34
47
40
60
52
66
57
70
60
76
65
80
69
90
77
100
86
115
99
120
103
161
138
181
155
201
172
241
206
261
224
271
232
301
258
361
310
381
326
NOTE: Refer to the "Water Temperature Rise" table in the French
section of this manual for the metric (Celsius and liters) version
of this table.
6
80°F
90°F
100°F
GPH
GPH
GPH
20
18
25
22
30
27
35
31
45
40
50
44
53
47
57
51
60
54
68
60
75
67
87
77
90
80
120
107
135
120
108
151
134
120
181
161
145
196
174
157
203
181
163
226
201
181
271
241
217
286
254
229
Form No. EBOOSTERM-0321
English
Booster
Heater
kW
16
4
20
5
24
6
7
28
9
36
40
9.9
42
10.5
46
11.4
48
12
13.5
54
60
15
69
17.25
72
18
96
24
27
30
36
39
40.5
45
54
57

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Compact sérieMini-compact série

Table des Matières