Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications

Install DR65A3000 according to National Electric Codes.
Dry-Bulb Temp
80°F (26.7°C)
70°F (21.1°C)
60°F (15.6°C)
Home Size
(square ft) @
8 ft ceiling
2080
2600
3120
* Based on extreme climates where outdoor humidity is 70-90% RH. For less extreme climates, larger
homes can be adequately served with less capacity. Actual requirements may vary.
Dimensions in inches and (mm):
12 (305)
8 INCH (203)
12
DIAMETER
(305)
Product weight: 60lb (27 Kg)
Shipping weight: 68lb (31 Kg)
Shipping dimensions: 16.7" H × 17" W × 32.9" L
Media Filter: MERV 11, 9" H x 11" W x 0.75" D
Drain connection: 3/4" threaded female NPT
connection.
Duct connections: 8" round inlet and outlet. ABS
plastic, compatible for connection to rigid or
flexible ducting with sheet metal screws and/or
tape.
Cabinet: 20 gauge galvanized steel powder-coat
painted.
Insulation: R value 1
Compressor: Rotary-style, 6.1 KBTU
Refrigerant: R-410A, 15 oz.
Operating Temp Range (outside cabinet):
34ºF to 135ºF (1.1ºC to 57.2ºC)
Operating Humidity Range: 0-99% RH
4
Intake Humidity
Capacity (Pints/Day)
60% RH
65
60% RH
47
60% RH
34
Dehumidifier Capacity Required to Maintain Desired Indoor RH*
60% RH Indoor
(pints/day)
49–54
61–68
75–82
28-1/2 (724)
50% RH Indoor
(pints/day)
55–58
65–72
79–86
Airflow versus external static pressure
(0–1" water pressure) with collars
attached
0.2"
0.4"
M29763
0.6"
Input ratings
• Electrical input voltage: 120 VAC, 60 Hz
nominal
• Input current: 5.2 A
Output ratings
• Power transformer to R/C terminals:
24 VAC, 0.85 A
• Energy Performance: 2.22 liters (4.7 pints)
per kilowatt hour (KWH)
Standards and approval body
requirements
• ETL Listed per UL 474 and
CSA C22.2 No 92
• ENERGY STAR rated.
DR65A3000 Dehumidification System 33-00297EFS—01
40% RH Indoor
(pints/day)
71–78
90–97
95–110
0"
160 CFM
140 CFM
120 CFM
100 CFM

Publicité

Table des Matières
loading

Table des Matières