NOTE: Discard the upper flue mounting bracket included with
the hood and use the one included in this kit.
Center the upper flue
1
mounting bracket over
the hood location and
lean its top against the
ceiling. Use this bracket
as a template to mark
the position of its screws.
Remove the mounting
bracket. Drill both screw holes using a 5/16" drill bit. Insert the
included drywall anchors into the drilled holes (one per hole).
Secure the upper flue mounting bracket to the wall using
2 no. 8 x 1¼" flat head mounting screws. Make sure that the
bracket is tight against the wall.
!
Be careful when installing the decorative flue and hood,
they may have sharp edges.
2
Remove
the
protective plastic
film
on
both
lower and upper
flues.
Attach
the Lower flue
m o u n t i n g
bracket to the
top back lower
HO0122A
flue
using
2 no. 8 x 7/16" screws. The center flange (A) must be down (see
illustration).
Carefully
the lower flue; the upper flue side flange being located outside
the bracket screw (see inset in the illustration). Leave about 2"
of the upper flue over the lower flue.
3
Place the hood on a table. Use a
piece of cardboard to avoid
damaging the table or the hood.
Using 4 no. 8 x 5/16" screws,
mount the metal air outlet to the
top of the hood. Remove all
protective plastic film on the hood.
4
Install the flue assembly over the
hood.
5
Insert each glass special flat heat
screw into their rubber spacer.
I
NSTALLATION
R
C
EILING
M
C L
BRACKET TOP
HD0332
AGAINST THE CEILING
WARNING
2"
A
slide
the
upper
flue
HJ0010
HO0123
HO0102
I
NSTRUCTION FOR
H
O
ANGE
OOD
Do not overtight the screws when assembling the glass
panel to the hood.
OUNTING
6
Carefully assemble the glass
panel to the hood, using the
4 special screws with spacer.
7
Align the hood and install it above
the
hood
(previously installed in step 5 of
the installation manual). Gently
lower the hood until it is hung to
the hood mounting bracket.
Using 2 no. 8 x 1¼" flat head screws,
secure the lower flue bracket
(shaded part in the illustration
beside) to the wall.
8
Slide a 6" steel round duct over
the metal air outlet, use duct tape
to seal the joint. Plug the hood
inside
power cord into the outlet.
9
Slide the upper flue until it is
aligned with its mounting bracket.
The bracket should be inside the
flue. Secure the upper flue mounting
bracket using 2 no. 8 x 5/16"
mounting screws.
10
Remove grease filter in order to
access hood inner mounting
holes. First, access grease filter by
opening the hood front panel.
Then, remove the grease filter by
pressing down on its metal latch
tab and tilt filter downward. Set
aside grease filter.
11
Drill both screw holes using a
5/16" drill bit through inner
hood mounting holes. Insert the
included drywall anchors into the
drilled holes (one per hole).
Secure the hood using 2 no. 8 x 1¼"
screws with 2 washers.
Go to step 8 in the installation manual to finalize the hood installation.
VJ70330SS
E
PTIONAL
XTENSION
CAUTION
LOCATIONS
HO0103
mounting
bracket
HO0124
HD0248
HD0252
HD0294
F
LUE
S
S
CREW
CREW
LOCATIONS
HJ0028
HO0125
I
H
NNER
OOD
M
H
OUNTING
OLES
08688

Publicité

loading

Sommaire des Matières pour Venmar jazz VJ70330SS

  • Page 1 VJ70330SS NSTALLATION NSTRUCTION FOR ANGE PTIONAL XTENSION NOTE: Discard the upper flue mounting bracket included with CAUTION the hood and use the one included in this kit. Do not overtight the screws when assembling the glass Center the upper flue panel to the hood.
  • Page 2 ’ IRECTIVES D INSTALLATION DU KIT DE RALLONGE VJ70330SS DE CONDUIT DÉCORATIF POUR LA HOTTE NOTE : Veuillez vous défaire du support de montage du conduit ATTENTION décoratif supérieur inclus avec la hotte et utiliser celui Ne pas trop serrer les vis lors de l’assemblage du inclus avec ce kit.