4.
Use
On the FireWare Cirrus you will find many knobs and connection points:
1.
Starter button
2.
Nozzle
3.
Charger connection
4.
Battery (battery with housing, circuit-board, fuse and connector)
5.
Battery connector
6.
Fluid hose
7.
Screws (Randel)
8.
Connection for the fluid hose
9.
Fluid tank
10.
3-pin XLR connection
11.
Battery Status Led
12.
Adjustment button
13.
Battery connection
Charging
The yellow led (11) on the FireWare Cirrus indicates the charge level of the battery and whether this
must be recharged. The led has 4 positions for this purpose:
1.
The led blinks slowly: the battery is charged between 15 and 100% and can be used.
2.
The led blinks rapidly: the battery is charged less than 15% and must be replaced or re
charged.
3.
The led burns continuously: There is a problem with the battery or the evaporator is
damaged. Please contact FireWare.
4.
The led doesn't burn, even though the battery is connected: Approximately 40 seconds
after the last puff of smoke, the Cirrus automatically goes into sleep mode. The power
consumption of the device is then only 1.5 mA. To restart the device, push on the start
button.
If the battery is drained, you can replace it or recharge. To replace it, remove the battery (4) from the
battery-connector (6). Unscrew the screws (7) and remove the battery from the machine. Fit a new
battery and screw in the screws again. Then reconnect the battery to the machine.