5.1. Adjustment
• The continuous signal of the yellow LED signals the actuator detection; the flashing of the yellow LED
signals that the safety switch is actuated in the hysteresis area.
• The correct functionality of both safety channels must be checked by means of the connected safety
monitoring module.
5.2. Actuating curves
• The actuating curves represent the typical switching distance of the safety switch during the approach of
the actuator subject to the actuating direction
• Preferred actuation directions: from front or from side
Lateral actuating direction
Frontal actuating direction
Safety Switch RFID
Actuating curve
Transverse misalignment
S [mm]
12
10
5
0
–20
–15
–10
–5
0
Actuating curve
• The axial misalignment (y) is max.
± 18 mm.
5
10 15
20
• Latching versions Y ± 3 mm.
Y [mm]
• The latching force will be reduced by mis
alignment.
31