9. Starting up

9.1 Menu structure

The [MENU], [ ], [ ] and the [OK] keys can be used to select the following programs.
Set timer
Menu
Set time delay
Menu
Set ventilation
Menu
Set temperature
Menu
Display status
Menu
Display malfunction history
Menu
Reset
Menu
The menus P1 and P2 are freely accessible while the menus P3 to P7
require an "access code" (352).
Accessing the menus
Order
Key
Display
1
Menu
P1
2
P2
3
"1 - -"
4
"3 - -"
5
OK
"- 2 -"
6
"- 5 -"
7
OK
"- - 3"
8
"- - 2"
9
OK
P3
10
P4
11
P5
12
P6
13
P7
Press [MENU] twice to exit the program. If no more keys are pressed, the program
will stop after five minutes and the display will return to the ventilation position.
The exception to this rule is menu P3. A period of thirty minutes applies here.
9.2 Example
Set the central position of the intake fan to 40%.
Order
Key
Display
1
Menu
P1
2
P2
3
"1 - -"
4
"3 - -"
5
OK
"- 2 -"
6
"- 5 -"
7
OK
"- - 3."
8
"- - 2"
9
OK
P3
10
OK
P31
11
P35
12
OK
50
13
40
14
OK
P35
15
MENU
P3
16
MENU
1
9.3 Set parameters
P1 Timer: Menu not in use. P2 Time delays
No. Description
21 Switch-on delay high position 0
Low voltage input
22 Switch-off delay high position 0
Low voltage input
P1
Menu not in use
P2
P3
P4
P5
P6
P7
Description
Timer
Time delays
Access code required (352)
First numeral of access code
Second numeral of access code
Third numeral of access code
Ventilation
Temperatures
Status
Malfunction history
Reset
Description
Timer
Time delays
Access code required (352)
First numeral of access code
Second numeral of access code
Third numeral of access code
Ventilation
Ventilation procedure
Select P35
Current setting
Select 40
Saves value 40
Ventilation position
Min.
Max.
Default Unit
15
5
Minutes
120
30
Minutes
P3 Ventilation
No. Description
31 Exhaust fan low position
32 Exhaust fan medium position
33 Exhaust fan high position
34 Intake fan low position
35 Intake fan medium position
36 Intake fan high position
37 Current exhaust fan position
38 Current intake fan position
P4 Temperatures
No. Description
41 Comfort temperature
42 Not applicable
43 Not applicable
44 Not applicable
45 Current value of T1
(outdoor air temperature)
46 Current value of T3
(return air temperature)
47 Current value of T4
(exhaust air temperature)
48 Not in use
49 Not in use
P5 Statuses
No. Description
0
51 Standard setting at "0"
52 Standard setting at "0"
53 Standard setting at "0"
54 Bypass present
No
55 Standard setting at "0"
Always leave P51, P52, P53 and P55 on "0". Setting at "1" will
cause malfunctions to be displayed.
P6 Malfunction history
No. Description
Display text
61 Last malfunction
Code conforms to alarm and malfunction read-
ing
62 One-but-last malfunction Code conforms to alarm and malfunction read-
ing
63 Two-but-last malfunction Code conforms to alarm and malfunction read-
ing
P7 Malfunctions
No. Description
71 Reset alarm/malfunction situation
72 Total reset: All default values are reset
In the case of total reset "P72", the "Bypass present" "P54" is set
at "0". Therefore, units with Bypass "P54" should be set back to
"1" after a total reset.
If "P54" is set at "1", return to the main menu using
[OK]-[MENU]-[MENU].
Reset is now complete. See §12 for a list of malfunctions.
34
Min.
Max.
Default Unit
15
98
30
%
16
99
50
%
17
100
90
%
15
98
30
%
16
99
50
%
17
100
90
%
Current value
%
Current value
%
Min.
Max.
Default Unit
15
28
18
°C
Current value
°C
Current value
°C
Current value
°C
1
Default
Yes
Dependent on model
0
1
Default
No reset Reset
0
No reset Reset
0