Troubleshooting; Transportation And Storage - Greencut GWP300X Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TROUBLESHOOTING

The table includes some of the most common problems, their causes and remedies.
PROBLEM
The pump
• Lack of fuel
motor does
• Fuel failure
not start.
The water
pump can
not pump.
NOTE: If you are unable to resolve the problem, please contact the Official Technical Service.

TRANSPORTATION AND STORAGE

Before transporting and / or storing the water pump, make sure it is completely cooled down.
Transport the water pump with the fuel switch off, as well as keeping it in a horizontal position to prevent fuel
spills.
Store this tool in a clean and dry place.
Clean the interior of the water pump prior to storage. After washing it, remove the water drain plug, completely
drain the water from the pump, and reinstall the water drain plug.
Pull the starter cord until you feel resistance, and then continue pulling until the triangle mark on the flywheel
matches the hole in the starter screw. In this position, the air inlet and the exhaust valves are both closed, and
this can prevent internal oxidation of the engine.
Cover the water pump to protect it from dust.
POSSIBLE CAUSE
SOLUTION
1. Check if there is enough fuel.
2. Check that the fuel cock lever is in the ON
position.
3. Check that there is fuel in the carburettor
bowl. Do it by disassembling the bowl screw.
1. Check if there is enough water.
2. Check if the filter on the end of the inlet
hose.
3. Check if the hose clamp is firmly tight.
4. Check if the water hose is damaged.
5. Check if the suction height required is too
high.
6. If the water pump still does not pump water,
please contact your dealer for assistance.