Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
8. INDICATIONS
Charger off (mains not
connected)
Charger just switched on and
showing the charge
characteristics
Stand-by
Charging
Full
Failure
= Off
= On
= Blinking
9. FAILURE REPORT INDICATIONS
If the charger does not function (anymore), it can be restarted by pulling the mains plug
from the wall socket and putting it back in again. First of all you should however follow the
indications in the next paragraphs based on the failure report indications.
9.1 Not a single LED is lig hting
• There is no mains voltage.
First check whether the plug has been fitted in the wall socket. If this has been
fitted in a wall socket it should be checked whether there is any voltage on the wall
socket. If there is no mains voltage then you should check the safety fuses in the
distribution cabinet or call a technician.

9.2 Both LED's light

If no battery is connected, this is a stand-by condition and no failure condition.
If a battery is connected however, one of the following failure conditions may have
occurred:
• There is no battery voltage present.
Check whether the battery has correctly been connected to the charger.
If it is not connected then the connection must be restored and the charging process
should be restarted.
• The polarity of the battery connected to the charger is not correct.
Check whether the polarity of the charger corresponds with the polarity of the battery.
If it is connected correctly then you should consult your supplier/dealer.
74
Yellow LED
Green LED
EXENDIS B.V.
Impulse S6-S8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Impulse s8

Table des Matières