WIRELESS - Function
DISPLAY
Other features
Bucket Full Light
Glows when the bucket is ready to be emptied, or
when the bucket is removed or not replaced in the
proper position.
Auto Defrost
When forst builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Note: When Auto defrosting operation, the unit
may make a voice of refrigerant flowing, it is normal.
Auto Shut off
The dehumidifier shuts off when the bucket is full,
or when the bucket is removed or not replaced in
the proper position. For some models, the fan
motor will continue to run for 30 seconds.
Auto-Restart
If the unit breaks off unexpectedly due to the
power cut, it will restart with the previous function
setting automatically when the power resumes.
Press this button for 3 seconds to initiate the Wireless connection mode. The
LED DISPLAY shows'AP' (at this time the unit shuts off all other functions) to
indicate you can set Wireless connection. If connection (router) is successful
within 8 minutes, the unit will exit Wireless connection mode automatically
and the Wireless indicator illuminates and the unit enters the previous
function. If connection is failure within 8 minutes, the unit exits the Wireless
connection mode automatically.
Shows the set % humidity level from 35% to 85% or auto start/stop time
(0~24) while setting, then shows the actual(±5% accuracy) room % humidity
level in a range of 30% RH(Relative Humidity) to 90%RH. (Relative Humidity)
Error Codes and Protection Code:
AS-Room temperture sensor error--Unplug the unit and plug it back in. If
error repeats, call for service.
ES/EH61-Evaparotor coil Temperature sensor error-- Unplug the unit and
plug it back in. If error repeats, call for service.
AS/EH60-Room temperture sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
P2-Bucket is full or bucket is not in right position-- Empty the bucket and
replaceit in the right position.
E4-Display panel communication error--Unplug the unit and plug it back in.
If error repeats, call for service. (on some units)
P1- Unit is defrosting--Allow the unit time to automatically service. The
protection will clear after the unit self defrosts. (On some models)
EH00-Indoor EEPROM error- Unplug the unit and plug it back in. If error
repeats, call for service. (On some models)
Description
Setting the Timer(With 1 indicator light)
·
Press to initiate the Auto start or Auto stop
feature, in conjuction with the UP and DOWN
buttons.
·
When the unit is on, press the Timer button to
actieve the Auto Stop feature. When the unit is
off, press this button to actieve the Auto start
feature.
·
Press or hold the UP or DOWN button to
change the Auto time by 0.5 hour increments,
up to 10 hours, then at 1 hour increments, up
to 24 hours. The control will count down the
time remaining until start.
·
The selected time will register in 5 seconds and
the system will automatically revert back to
display the previous humidity setting.
·
Turning the unit On or Off at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
·
When LED display window displays the code of
P2, the Auto Start/Stop function will also be
cancelled.
18
EN