2-outlet Water timer
With Digital Display
059-3230-0
PROGRAMMING FOR THE DIGITAL OUTLET OF THE TIMER
■
THE MANUAL OUTLET CANNOT bE PROGRAMMED DIGITALLy
■
INSTALLING THE bATTERIES
Remove the tray on the back of the timer by
■
sliding it out.
Insert two AA (1.5 V) alkaline batteries
■
(not included) and replace the tray.
Replace batteries when low battery icon appears.
■
INSTALLATION
Attach timer to an outdoor hose faucet and turn
■
on after programming.
PROGRAMMING THE TIMER
Rotate the dial to positions indicated for setup.
■
SET CLOCK
Press the + button to advance clock time
■
(hold button for quick advance).
Press the – button to reverse clock time
■
(hold button for quick reverse).
Downloaded from
www.Manualslib.com
START TIME
Press the + button to advance start time
■
(hold button for quick advance).
Press the – button to reverse start time
■
(hold button for quick reverse).
HOW LONG
Set watering duration from 1 to 240 minutes using
the + and – buttons.
HOW OFTEN
Set watering frequency as every 6 hrs, 12 hrs, or
from 1 to 7 days using the + and – buttons. 1 is
every day, 2 is every other day etc. up to 7 days.
AUTO
Timer waters according to programmed time,
duration, and frequency.
RAIN DELAy
When in AUTO, press + button for 24 hrs,
■
48 hrs, or 72 hrs.
Screen will flash between clock and hours
■
remaining before programmed cycle resumes.
To remove rain delay, turn dial to OFF and then
■
back to AUTO.
MANUAL/HAND WATERING
To water without interrupting the set cycle, press
[MANUAL] button and then use + and – buttons to
set from 1 to 240 minutes.
To remove manual watering (turn off),
■
turn dial to OFF.
To resume programmed cycle turn the
■
dial back to AUTO.
manuals search engine
MANUAL OUTLET
Working Water Pressure
The manual port of the timer gives access to the
Minimum: 25 psi Maximum: 100 psi
hose faucet without interrupting the programmed
Working Temperature
cycle of the digital outlet.
Maximum: Do not exceed 120 degrees F
Open the valve in the outlet by turning the lever
■
Minimum: Keep from freezing
counterclockwise to the open position.
Warnings
Close the valve by turning the lever to the
■
For outdoor use with cold water only.
closed position.
TROUbLESHOOTING
Water does not come on at desired time.
Check if:
Clock is set to correct time including AM and PM.
■
Start time is set to desired time including
■
AM and PM.
Rain Delay is on.
■
Timer does not water.
Check if:
Faucet is on.
■
Timer is set to AUTO.
■
Hose faucet is on.
■
Batteries are low.
■
Clock is set to correct time including AM and PM.
■
Rain Delay is on.
■
Water won't turn off.
Check if:
Watering duration is set to desired time.
■
Start times begin after previous watering cycle
■
has run through all stations and set durations.
For bypass/manual outlet: close valve.
■
Imported by yardWorks Canada Toronto, Canada M4S 2b8
PN 91234-24 rB