Your Hayward Matrix pump has been quality-built and
engineered to give you many years of efficient, dependable
service. The non-conductive, corrosion-proof motor housing
provides protection from the elements and insulates the
electrical motor parts from outside contact.
The advanced design reduces operation and maintenance to
simple, common-sense procedures.
GENERAL TIPS ON PUMP INSTALLATION
For best pump performance, locate the system below the pool
water line and as close to the pool as possible. If you own an
above ground pool please see Note: NSPI- 4 Article V, for safe and
proper installation of the equipment package. Make sure suction
joints are tight. Suction pipe should be as large or larger than
discharge pipe.
Damp, non-ventilated locations should be avoided. Motors
require free circulation of air to aid in cooling.
Insure that the electrical supply available agrees with the
motor's voltage, phase and cycle, and that wire size is adequate
for the HP/KW rating and distance from the power source. Motor
must always be properly grounded. If cord connected, use only
a properly grounded outlet. Electrical circuits should be
protected by proper size ground fault circuit interrupter (GFCI).
All electrical wiring should be performed by qualified personnel
and must conform to local codes and regulations.
1.
Clean strainer basket regularly. Do not strike basket to clean.
Inspect strainer cover gasket regularly and replace as necessary.
2.
Hayward pumps have self-lubricating motor bearings and shaft
seals. No lubrication is necessary.
3.
Keep motor housing clean. Insure air vents are free from
obstructions, debris, etc.
MANUFACTURED EXCLUSIVELY BY HAYWARD
2880 PLYMOUTH DRIVE, OAKVILLE, ONTARIO L6H 5R4 • (905) 829-2880
® Hayward Pool Products Canada, Inc. -- Licensee
HAYWARD Hi-Performance SELF-PRIMING PUMPS
INSTALLATION AND OPERATING INSTRUCTIONS
TM
MAINTENANCE
www.haywardcanada.com
STARTING AND PRIMING INSTRUCTIONS
Fill strainer/housing completely with water. Never operate the
pump without water. Water acts as a coolant and lubricant for
the mechanical shaft seal.
Open all suction and discharge lines and valves, as well as air
bleed (if available) on filter. (The air that is to be displaced from
the suction line must have some place to go).
Turn on power and allow a reasonable time for priming. Priming
time depends on suction lift and length of suction piping. If
pump will not start, or will not prime, see TROUBLE SHOOTING
GUIDE on back page.
Note: NSPI-4 Article V, standard for above ground and on
ground pools, advises that components such as the filtration
system, pumps and heater be positioned so as to prevent their
being used as a means of access to the pool by young children.
4. Occasionally, shaft seals must be replaced, due to wear or
damage. See instructions
STORAGE/WINTERIZING
Pump and motor must be protected from freezing. Shut off all
electric power. Disconnect cord/electrical connections and
plumbing connections. Drain thoroughly and clean out any
debris. Store pump and motor in a dry, well ventilated room.
5600
08T
IS
HC-
loading

Sommaire des Matières pour Hayward Matrix SP5610

  • Page 1 5600 HAYWARD Hi-Performance SELF-PRIMING PUMPS INSTALLATION AND OPERATING INSTRUCTIONS Your Hayward Matrix pump has been quality-built and engineered to give you many years of efficient, dependable service. The non-conductive, corrosion-proof motor housing provides protection from the elements and insulates the electrical motor parts from outside contact.
  • Page 2 PARTS LISTING Ref. No. Part No. Description No. Required SPX5500DL Strainer Cover SPX5500H Strainer Cover ‘O’ Ring SPX5500F Strainer Basket SPX5500G Strainer ‘C’ Clip SPX5500C Strainer Housing SPX1700FG Drain Plug w/Gasket SPX5500K Strainer ‘O’ Ring SPX0714Z4 #13-9 x 1” Phillips, Pan Head Screw SPX5500B Pump Cover SPX5500J...
  • Page 3 WARNING - To reduce the risk of injury, do not permit children to use this product. B. Disconnect all electrical power service to pump before beginning shaft seal replacement. C. Only qualified personnel should attempt rotary seal replacement. Contact your local authorized Hayward Dealer or service center if you have any questions.
  • Page 4 SERVICE AND REPAIRS Consult your local authorized Hayward dealer or service center. No pumps or motors may be returned directly to the factory without the express written authorization of Hayward Pool Products Canada, Inc.
  • Page 5 HAYWARD INSTRUCTIONS POUR L’INSTALLATION ET LE FONCTIONNEMENT Votre pompe Matrix de Hayward a été conçue et fabriquée avec un soin minutieux en vue de vous procurer un rendement fiable et efficace pendant de nombreuses années. Le carter du moteur non conducteur à...
  • Page 6 Nombre N˚ de réf. NUMÉRO DE PIÈCE DÉSIGNATION requis SPX5500DL Couvercle de la crépine en Lexan transparent SPX5500H Joint êtanche du couvercle de la crépine en Laxan transparent SPX5500F Panier SPX5500G Pince ‘c’ pour crépine SPX5500C Crépine SPX1700FG Bouchon vidange et rondelle (facultatif ) SPX5500K Joint torique SPX0714Z4...
  • Page 7 B. Débrancher toute alimentation électrique à la pompe avant d’effectuer le changement du joint d’étanchéité de l’arbre. C. Le remplacement du joint rotatif devrait être effectué par un professionnel qualifié seulement. Contacter un détaillant autorisé Hayward local ou le centre de service Hayward.
  • Page 8 ENTRETIEN ET RÉPARATION Consulter votre dépositaire ou centre d'entretien Hayward autorisé régional. Aucune pompe ni aucun moteur ne doivent être retournés directement à l'usine sans le consentement préalable par écrit de Produits de Piscines Hayward Canada, Inc. www.haywardcanada.com...