INSTALLATION MANUAL
2505GTL—Grand Traditional Logs
For Valor 2500K fireplaces ONLY
Special procedure BEFORE you install the
2505GTL logs in certain conditions
ONLY when meeting following condition (other
installations, proceed to next page):
• IF vent system vertical rise is at minimum, as de-
scribed in fireplace installation manual (does not
apply if vent system is higher than minimum rise)
The air shutter stopper must be replaced.
1. If already installed, remove the fuel bed black steel
platform by lifting it up.
2. Remove the burner, detaching 3 screws, 2 on the
left and 1 on the right, then sliding it to the right to
disengage it and lifting it out.
3. Locate the air shutter stopper on top of the aera-
tion block.
Natural
Gas
Propane
Gas
4. Remove two screws holding the stopper and
replace with the air shutter stopper included with
the GTL logs securing it with the two screws in the
position shown below, regardless of gas used.
New
Stopper
must be
in this
position
4009840-01
@2025 Miles Industries
LT1 Series
Reinstall the burner
To reinstall the burner,
1. Slide the burner tube into the injector block under-
neath.
2. Once the burner is in place, secure its left end to
the bracket with 2 screws and its right end to the
end bracket with 1 screw.
Fixing points
Injector block
3. Install the fuel bed as instructed starting next
page.
Grand Traditional Logs
Traditional Log #1—left
Traditional Log #2—front left
Traditional Log #3—center left
Traditional Log #4—center right
Traditional Log #5—front right
Traditional Log #6—right
Traditional Log #7—rear top left
Traditional Log #8—rear top right
Traditional Log #9—RH Ember, rear
Traditional Log #10—LH Ember—rear
High temperature black embers—small
(3 cups)
Ember chunks (3)
Air shutter stopper
Top view
Fixing
point
Tube
Front / side view
2505GTL
4009754
4009755
4009756
4009757
4009758
4009759
4009760
4009761
4009762
4009763
4009842
4008764
4012685
1