30" GAS SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage, personal injury
or death.
FOR YOUR SAFETY:
— Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
Shave
Raised
Edge
to Clear
Space
for a 31½"
(81 cm) Wide
Cooktop.
Locate Cabinet Doors 1" (2.5 cm)
Min. from Cutout Opening.
For existing 29" (73.7 cm) cutout width opening,
you must call the Service Center for optional thinner
side panels. Also you must prepare the countertop
edge as shown in the "Countertop Preparation"
section (see page 4).
A. HEIGHT
35 5/8" (90.5 cm) -
36 5/8" (93cm)
NOTE: Wiring diagram for these appliances are enclosed in this booklet.
Printed in United States
Frigidaire FFGS3025L / FGS365EB
(Models with Sealed Top Burners)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
These surfaces should be flat
& leveled (hatched area).
1 ½" Max.
From Wall Both Sides
(3.8 cm Max.)
C. COOKTOP
B. WIDTH
WIDTH
31½" (80 cm)
30" (76,2 cm)
(76.2 cm Min.)
30" Min.
1/2" Min.
(76.2 cm) Min. (see
5" Min.
(12.7 cm Min.)
31 1/2"
(81 cm)
Exact
G
F
Grounded Jonction Box or Wall Outlet Should Be Located 8"
to 17" (20.3 cm to 43.2 cm) From Right Cabinet and 2" to 4"
E. CUTOUT WIDTH ***
D. DEPTH TO
(Countertop and Cabinet)
FRONT OF RANGE
28 5/16" (71,9 cm)
30±1/16"
(76,2±0,15 cm)
1
Refer to your serial plate for
applicable agency certification
Appliances Installed in the
state of Massachusetts:
This Appliance can only be installed
in the state of Massachusetts by a
Massachusetts licensed plumber or
gasfitter.
This appliance must be installed
with a three (3) foot / 36 in. long
flexible gas connector.
A"T" handle type manual gas valve
must be installed in the gas supply
line to this appliance.
30" Min.
Note 3)
18" Min.
(45.7 cm) Min.
E
1/4" min.
1/2" min.
Approx. 1 7/8"
(4.8 cm)
(5.1 cm to 10.2 cm) From Floor.
F. CUTOUT
DEPTH
21 3/4" (55,2 cm) Min.
22 1/8" (56,2 cm) Max
24" (61 cm) Min. with
backguard
P/N 318201673 (0711) Rev. C
Wiring Diagrams - pages 31-32
13"
(33 cm)
24" Min.
(61 cm Min.)
G. HEIGHT
OF COUNTERTOP
36 5/8" (93 cm) Max.
35 5/8" (90.5 cm) Min.
English – pages 1-9
Español – páginas 10-18
Français - pages 19-28