Installing The Downdraft Vent - Dcs Dd-30Ss Installation Guide

Table des Matières
Les langues disponibles

Les langues disponibles

CUT-OUT DIMENSIONS (WITH DOWNDRAFT)
Rear of Downdraft Cutout
Rear Edge of Cooktop
5" Min.
clearance
to combustible
surface
INSTALLING DOWNDRAFT VENT
1) Remove the unit from the carton
and place on a flat surface for
assembly. Cover the surface to
prevent accidental damage.
Remove all downdraft parts
including
the
6
mounting
brackets, 2 end caps, 16 screws,
literature package, and backdraft
damper.
2) Attach the overcounter support
arms to the left and right sides of
the downdraft body as indicated
in Fig. 08. Two short screws are
provided. Attach the end caps to
the left and right sides of the
downdraft over the overcounter
support arms. Attach the lower
support legs to left and right
sides of the downdraft into the
threaded slots on each side.
INSTALLATION INSTRUCTIONS
DROP-IN COOKTOP (MISC. BRAND)
33-1/2" (DD-36)
1/2" Min.
27-1/2" (DD-30)
1-3/4"
*
* Measured from the rear edge of cooktop to rear of downdraft
cutout. It is recommended that the installer draw the cooktop
and downdraft cutouts on the countertop before making any
cutouts to avoid mistakes.
Fig. 06a
25 "
CUTOUT DEPTH
COOKTOP
36 "
22-1/2"
3/4"
8
1/2" min.
V
E
N
T
1/4"
COOKTOP
3/4"
24 "
FIG.07
1-7/8"
1/4"
FRONT
COUNTERTOP
VENT

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Dcs dd-30ssDcs dd-36ss

Table des Matières