Direct Electrical Connection To The Circuit Breaker, Fuse Box Or Junction Box - Frigidaire Fcs388Whcd Instructions D’installation

Table des Matières
Les langues disponibles

Les langues disponibles

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
Four Conductor Wire Connection to Range
(mobile homes)
1. Remove the 3 screws at the lower end of the rear
wire cover, then raise the lower end of the rear wire
cover (access cover) upward to expose range
terminal connection block (see Figure 3).
2. Remove the 3 loose nuts (after you remove the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where the ground strap was removed (see Figure 5).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
6. Replace the 3 nuts on the terminal block (see Figure
5).
7. Lower the terminal cover and replace the 3 screws.
Terminal Block
Black Wire
1 1/8" (2.9 cm)
Dia. Direct
Connection
Hole. Punch
Out Knockout
for 1 3/8 (3.5
cm) Dia. Cord Kit
Hole.
A User Supplied
Strain-relief Must
Be Installed at
This Location
NOTE: Be sure to remove the
supplied grounding strap.
Downloaded from
www.Manualslib.com
(Models with an Electric Oven and a Gas Cooktop)
Silver Colored Terminal
Neutral
(White Wire)
Ground (Bare
Copper Wire)
To 240 V Receptacle
Figure 5
manuals search engine
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end of
the cable. At the appliance end, the cable goes through
the Direct Connection Hole (see Figure 5) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire
(see Figure 6):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Neutral
(white) Wire
Red
Red
Wires
Wire
Green
(or Bare Copper)
Wire
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
5
Cable from Residence
Black
Wires
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
Cable from
Appliance
Figure 6
Junction
Box
Table des Matières
loading

Table des Matières