Motor Direction; Basic Settings - Chamberlain Sl600Ulc Manuel D'installation

Table des Matières
Les langues disponibles

Les langues disponibles

Installation (continued)

Motor Direction

Before programming, move the gate manually in the middle
position and re-engage manual disconnect release mechanism
(see page 12). Press and hold the "–" button on the control
board and ensure that the motor is moving in CLOSE direction. If
correct, immediately let go of the "-" button and gate stops.
If motor is moving in OPEN direction, go to the functions "d1" and
change the direction settings.
Once CLOSE direction is set correctly, leave the gate in the
middle position. The operator is ready for the Learning phase.
NOTE: Gate can be moved with "+" and "-" buttons prior to final
settings if required.
Press and hold the "+" button on the control board to move the
gate into OPEN position. When button is released operator stops.
Press and hold the "–" button on the control board to move the
gate into CLOSE position. When button is released operator stops.

Basic Settings

Basic Settings Overview
LED
AP
Application
d1
Direction Motor 1
LL
Limit Learning Phase
Application Settings
Application function shown on display.
This function is already pre-set at factory at correct value as
defined for the delivered operator.
No application selected
Sliding gate, SL600ULC and SL1000ULC (default)
Note: After a Factory Reset, you have to go into AP and set to 01.
Direction Motor Settings
Direction Motor function shown on display
Defines movement direction of the Motor.
Make sure to manually place the gate in the middle position
and reengage it. Press the – button to verify the direction of
operation, the default direction for the – button is close, release
the – button to stop the gate movement. To change the motor
direction, use the following steps:
1.
Press and hold the P button for 5 seconds. On the display you'll
see AP; this means you have accessed the function menu.
2.
Use either the + or – button to navigate to d1.
3.
Press and release P to enter the d1 menu.
4.
Use the + and – buttons to navigate between settings.
Function
Basic Settings (mandatory)
Motor is installed on left hand side (default).
Motor is installed on right hand side.
5.
Press and release P to select setting.
6.
Press and hold the P button for 5 seconds to exit the menu
and go back to the main display.
NOTE: If the motor direction is changed at any time after the
initial installation, an obstruction test must be performed, and the
limits must be relearned.
Limit Learning
Before Limit Learning Phase can be started the preparation
for the learning of the end limit position must be done as
described in the section Limit switch position Set up.
Assure that the Limit positions are checked and the door is in the
middle position to start the Limit Learning Phase.
Before starting a Learning phase ensure that:
1.
Other Basic Settings are completed
2.
Bracket for limit switch are installed and working correctly
3.
First movement will be in CLOSE direction
Available Learning methods:
Standard Learning Mode (Automatic)
1.
OPEN the LL menu.
2.
Press and hold "+ and –" buttons for 2 seconds.
3.
Automatic learning process starts. LL will flash on the
display during complete process.
4.
Gate moves in CLOSE direction until the CLOSE limit switch
is reached, and stops for 2 seconds., then moves in the
OPEN direction.
5.
Gate moves in OPEN direction until the open limit switch is
reached.
6.
Gate moves in CLOSE direction until the close limit switch is
reached, and stops.
7.
Standard Learning phase is finished. LL will appear on display
and board will return in stand-by mode after 3 seconds.