EZ1-LV Quick Installation Guide
EZ1-LV system installation
The EZ1-LV APsystems Microinverter is used in balcony and DIY systems which comprised of the below key elements:
PV modules; Power Cord; EZ1-LV microinverter; Router; Cell phone.
EZ1-LV microinverters have 2 input channels with independent MPPT and high input current and output power to adapt
to today's larger power module. Users could directly connect to the Wi-Fi version of EZ1-LV with their cell phones
through Bluetooth and get the real-time data of the solar systems. Besides direct connection, Wi-Fi version of EZ1-LV
could also connect to a router through Wi-Fi and send data to cloud servers for remote monitoring.
Through a power cord provided by APsystems, EZ1-LV could be plugged into a socket and start output energy, truly
easy and convenient grid connection.
NOTE: 1. If the wireless signal in the area where the microinverter is weak, it is necessary to add a Wi-Fi signal booster
at a suitable place between the router and the microinverter.
2. The EZ1-LV product is only suitable for the following DIY application scenarios, such as balcony, garden, garage, and
carport. The EZ1-LV is not suitable for the rooftop system application scenario.
3. Under good sunlight conditions, microinverters can operate with the rated output power, in the status of power
limiting or peak clipping.
4. The EasyPower App supports monitoring of 4 products from the EZ1-LV.
Step 1: Verify that grid voltage matches microinverter rating
Step 2: Install the microinverters in proper position
×
Do NOT carry the microinverter by the AC cable.
This may cause the AC cable to partially or fully
disconnect from the unit, resulting in no or poor
operation.
The Microinverter EZ1-LV can be installed on the balcony wall or fixed to the railing using cable ties. Select an appropriate installation method based on your actual scenario to ensure
that the EZ1-LV is securely installed.
NOTE: 1. Install the microinverters in proper position to avoid direct exposure to rain, UV or other harmful weather events.
2. Customer using fixing bolts or cable ties, please prepare them by yourself.
Step 3: Connect APsystems microinverters to the PV modules
When plugging in the DC cables, the microinverter should immediately blink
green ten times. This will happen as soon as the DC cables are plugged in
and will show that the microinverter is functioning correctly. This entire check
function will start and end within 10 seconds of plugging in the unit, so pay
careful attention to these lights when connecting the DC cables.
NOTE: 1.Each PV panel must be carefully connected to the same channel.
Make sure to not split positive and negative DC cables into two different input
channels: microinverter will become damaged and warranty will not apply.
2. Please ensure each DC cable's length within 3 meters.
Step 4: Connect the APsystems microinverter to power cord
①
① Remove the bus cable Y-CONN protective sleeve before power cord connection.
② Best Practice: Use the Unlock Tool to disconnect the connectors. (The Unlock Tool is included in the package, please safekeeping.)
③ Single device: Insert the microinverter AC connector into the power cord connector. Make sure to hear the "click" as a proof of robust connection.
④ Two device: The microinverter can also have two units connected in parallel to the power line.
NOTE: If the dual parallel bus cable and power cord are not included in the package and should be purchased separately. Please contact the salesperson or your dealer for details.
Step 5: Insert the power cord into the socket
Connect the EZ1-LV
AP EasyPower offers two modes "Direct Connect Mode"and "Remote Mode" to monitor the device.
Direct Connect Mode: APP connects to Bluetooth of the device, so that users can realize local monitoring
and control of the device.
Remote Mode: Login account, users can realize remote monitoring and control of the device.
NOTE: 1.In the absence of Wi-Fi, users can monitor and control the device in direct connection mode.
2.You are able to link up to 4 devices to your account, just repeat the linking device operations until
linking all your devices
Monitor & Control
On this page, user can visualize:
- Live Data: The real-time data of the device in current round, including the power, energy, running time,
working status and the cloud status.
·Working status
Normal: The device is working normally. Alarm: The device has alarms and you need to check it.
·Cloud status
Online: The device is connecting the cloud service through the internet. Offline: The device is not
connecting the cloud service through the internet, maybe the device is not connected the Wi-Fi or the
router is down.
- Benefits Overview: The lifetime energy produced by the device and the equivalent CO2 reduction.
By pressing "alarm icon" to check the alarm information if the device status is alarm.
By pressing "setting icon" to set the device. The setting page is shown below.
NOTE: For Connection and monitoring operation mode, please refer to the AP EasyPower User Manual.
Power Cord
Click
②
NOTE: If the microinverter is connected to
grid by plug, please comply with the local
regulation about the power limit.
→
③
Install APP
· Go to App Store
· Search "AP EasyPower"
· Download and install
NOTE: iOS: 10.0 and up
Please scan this QR code to
have access to our APPs.
1
P V M od ul es
Pow er C ord
W i -Fi
Router
E Z 1-LV M i c roi nverter
Bl uetooth
C el l P hone
Or
Dual Parallel Bus Cable
Power Cord
→
· Go to Google Play Store
· Search "AP EasyPower"
· Download and install
NOTE: Android: 7.0 and up
I nternet
C el l P hone
④