AUTOMATIC MAKE-UP AIR DAMPER
WITH TRANSFORMER AND
RELAY
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
2. Do not use the unit in conjunction with any exhaust device other
than compatible BEST or Broan range hoods.
3. This unit is not designed to provide combustion air for fuel-
burning appliances.
4. Do not connect the unit directly to a combustion appliance of
any type.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
6. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
7. When performing installation, servicing or cleaning the unit, it is
recommended to wear safety glasses and gloves.
8. During extreme weather events including snow storms, ensure
that the intake area for the outside air duct is not blocked and
able to provide a clear pathway for outside air to enter the
system.
9. When cutting or drilling into wall or ceiling, do not damage
electrical wiring or other hidden utilities.
10. When notching or drilling into framing including floor supports,
rim joists, and wall studs, comply with code and manufacturer
limitations on allowable modifications to these structural
members.
11. This unit is intended to be installed within the home in a location
protected from moisture.
12. This unit must be in an accessible location which allows for
inspection of the unit.
13. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in this document.
14. When federal, provincial or state legislation comprises more
restrictive installation and/or certification requirements, the
aforementioned requirements prevail on those of this document
and the installer agrees to conform to these at his own expense.
FOR RESIDENTIAL USE ONLY
https://manual-hub.com/
To register this product
visit: www.broan.com
CAUTION
1. Do not locate outside air inlet near hazardous materials or explosives.
2. Unit shall not be installed to introduce air from crawlspaces, garages,
attics, adjacent dwelling units, or other locations within the building
shell. Unit shall be installed to introduce air directly from outdoors.
3. Do not run the outside air duct directly above or closer than 2 ft to
any furnace or its supply plenum, boiler, or other heat producing
appliance.
4. Any ductwork used in conjunction with the Damper must be installed
in compliance with all local and national codes that are applicable.
5. Do not operate the Damper for fresh air introduction until all system
filters, including the central duct system filter, have been installed per
the system design.
6. Please read the unit specification label on the product for further
information and requirements.
7. The Damper's outdoor air intake, ducting, and any filters should be
inspected and maintained on a regular basis.
8. Insulate the duct and damper to prevent build-up of condensation in
cold weather climates. Vapor barriers on both sides of insulation are
recommended.
MODELS SMD6 • SMD8
Page 1
Table des Matières
loading

Sommaire des Matières pour Broan LinkLogic RELAY SMD6

  • Page 1 2. Do not use the unit in conjunction with any exhaust device other any furnace or its supply plenum, boiler, or other heat producing than compatible BEST or Broan range hoods. appliance. 3. This unit is not designed to provide combustion air for fuel- 4.
  • Page 2: Plan The Installation

    MODELS SMD6 • SMD8 Page 2 PLAN THE INSTALLATION • Outside air intake is placed high enough above grade to prevent blockage from snow or other debris such as leaves, and at a Planning the installation first requires selecting the most appropriate minimum of 1’...
  • Page 3 INSTALL THE DAMPER LINKLOGIC TECHNOLOGY ® The LinkLogic technology was specially designed for select Broan ® CONNECT TO and BEST ventilation devices to provide control and device sta- 24V TRANSFORMER tus information over existing power lines in the home. Extra control...
  • Page 4 MODELS SMD6 • SMD8 Page 4 INSTALL LINKLOGIC RELAY ® 1. Individually cap LinkLogic Relay’s yellow and violet wires to ® isolate them from contacting ground or any other electrical connection. 2. Bring LinkLogic Relay to electrical box with model C909 Tri- ®...
  • Page 5: Frequently Asked Questions (Faqs)

    Overall, the Damper let’s your Broan or BEST exhaust devices do their job more effectively and without interfering with the proper 5. Does ASHRAE 62.2-2007 – “Ventilation and operation of other home systems.
  • Page 6: Clapet Automatique D' A Ir De Compensation Avec Transformateur

    2. N’utilisez cet appareil avec aucun dispositif d’évacuation non 3. Ne placez pas le conduit d’arrivée d’air extérieur directement compatible avec les hottes de cuisine BEST ou Broan. au-dessus d’un appareil de chauffage, d’un caisson de distribution ou d’une chaudière, ni à moins de 60 cm (2 pi).
  • Page 7: Planification De L'installation

    MODÈLES SMD6 • SMD8 PLANIFICATION DE Page 7 L’INSTALLATION • Le clapet d’air de compensation ne doit pas aspirer l’air d’un vide sanitaire, d’un garage, d’un grenier, d’un logement adjacent ni de tout autre espace situé à l’intérieur de l’édifice. Le clapet doit être La planification de l’installation exige d’abord le choix du mode installé...
  • Page 8: Installation Du Clapet

    ® La technologie LinkLogic ® a été spécialement conçue pour certains appareils de ventilation Broan et BEST afin de commander et CONNECTER AU TRANSFORMATEUR 24V d’offrir de l’information sur l’état des appareils par le biais des lignes VERS LE RETOUR D’ A IR électriques de la maison.
  • Page 9: Procédure De Réinitialisation D'usine

    MODÈLES SMD6 • SMD8 INSTALLATION DU RELAIS Page 9 24 VAC SE CONNECTER À AMORTISSEUR MOTEUR LINKLOGIC® 1. Coiffez chacun des fils jaunes et violets du relais LinkLogic® afin de les isoler de tout contact avec la terre ou toute autre connexion électrique.
  • Page 10: Foire Aux Questions (Faq)

    De plus, certains ventilateurs comme ceux des grandes hottes évacuent Le Clapet automatique d’air de compensation Broan (le « clapet ») beaucoup plus d’air que celui pouvant être remplacé par les fentes et permet l’entrée d’air frais dans l’habitation lorsqu’un dispositif...
  • Page 11 2. No utilice la unidad en conjunto con dispositivos de extracción que no sean pies (60 cm) de cualquier caldera o su pleno de suministro, calentador u otro campanas BEST o Broan compatibles. aparato que genere calor. 3. Esta unidad no está diseñada para suministrar aire de combustión para los 4.
  • Page 12: Instalaciones Típicas

    MODELOS SMD6 • SMD8 PLANEACIÓN DE LA Página 12 INSTALACIÓN • La entrada de aire exterior se coloca a suficiente altura del rasante para prevenir que sea bloqueada por nieve u otros residuos como hojas, y a un mínimo de 1 pie (30 cm) por arriba del rasante. •...
  • Page 13 ® La tecnología LinkLogic ® se diseñó especialmente para ciertos dispositivos de ventilación Broan y BEST, para brindar información CONECTE AL TRANSFORMADOR DE 24 V de control y de estado del dispositivo sobre las líneas eléctricas AL AIRE DE RETORNO existentes en la casa.
  • Page 14 MODELOS SMD6 • SMD8 Página 14 INSTALACIÓN DEL RELÉ 24 VAC CONECTAR CON AMORTIGUADOR DE MOTOR LINKLOGIC® 1. Tape individualmente la punta de los cables amarillo y violeta del Relé LinkLogic® para aislarlos y prevenir el contacto con tierra o cualquier otra conexión eléctrica.
  • Page 15: Preguntas Frecuentes

    En general, el regulador permite que sus dispositivos de extracción mientras que el aire fresco de repuesto se lleva a la casa, Broan o BEST realicen su función con más eficacia y sin interferir con mejorando la ventilación. la operación adecuada de los demás sistemas de la casa.
  • Page 16 Periodo y exclusiones de la garantía: Broan (la “Compañía”) garantiza al consumidor comprador original de su producto (“usted”) que el producto (el “Producto”) estará libre de defectos en materiales o en mano de obra, por un periodo de un (1)

Ce manuel est également adapté pour:

Linklogic relay smd8

Table des Matières