Parameters and Functions

10
bEd: (+) or (-) to set the desired temperature for
grams P1-P9
11
Out: (+) or (-) to set the desired temperature for
grams P1-P9
12
InP: (+) or (-) to set the desired temperature for
mote operation .
Diagnostic function:
closed contact.
20
deG: Temperature units - °C Celsius or °F Fahrenheit
21
Time format
24H (24:00) or 12H (12:00 AM/PM)
22
dSt: Summer time change.
ual change of time. Date is not used.
30
AirC: Calibration of the room temperature display ±5°C/±8.5°F.
The calibration should be done after 1 day's operating with the
same set temperature. Place a thermo-meter close to the control-
ler and check the temperature in the room after 1 hour. When
you enter the calibration parameter,
that no calibration has been made. To enter the value shown on
the thermo-meter, use (+) and (-) keys to enter the real value.
OK
Then press
to confi rm. The message
the value will be stored in the internal memory. You can cancel
the calibration by pressing
31
OutC: Calibration of outdoor temperature sensor ±10°C/±17°F.
The same calibration procedure described for 30 AirC, except
for the location of the thermometer.
40
LANG Fr/EN: Change of language. Use (+) or (–) keys to se-
lect French or English.
70 rF
70 rF INI: New wireless connection of room temperature unit
INI
and antenna. The message
blinks in the display. After a connection has been estab-
71
lished, parameter
signal strength.
Please, note that parameter
nection has been established between room unit and antenna.
71
71 rF -XX.X: Control of the signal strength between room tem-
rF -
perature unit and antenna.
XX.X
The function is used to fi nd a suitable location for the room unit.
Green OK-LED indicates good connection. Blinking or steady
red light indicates insuffi cient signal strength.
The display shows the signal strength.
80
Clr ALL: Resetting to factory settings.
Note: Ensure that you have all necessary information to reset
your installation before using this function.
OK
Press and hold the
and parameters in this menu to factory settings. User programs
will also be reset.
90
Software version
99
End: Press the
OK
normal operation.
Reservations for product improvements.
The frame around the symbol shows
YES
automatic change.
no
is displayed to indicate
YES
is displayed and
OK
and then
.
"INI"
is shown and the symbol
will automatically appear for checking the
70
cannot be selected when a con-
key for 10 seconds to reset tempera-tures
key to exit parameter menu and return to
in pro-
in pro-
during re-
no
man-
7

Publicité

Table des Matières
loading

Table des Matières