• Disconnect the product from the electric
connection before starting any work on
the electrical installation. There is an
electric shock hazard.
• Connect the product to a grounded out-
let/line protected by a miniature circuit
breaker of suitable capacity as stated in
the "Technical specifications" table. Have
the grounding installation made by a
qualified electrician while using the
product with or without a transformer.
Our company shall not be liable for any
damages that will arise due to using the
product without a grounding installation
in accordance with the local regulations.
• The product can only be connected to the
mains electricity connection by an au-
thorized and qualified person, and the
warranty of the product starts only after
correct installation. The manufacturer
cannot be held responsible for any dam-
ages that may arise due to operations by
unauthorized persons.
• The electric cable must not be crushed,
folded, jammed or touch hot parts of the
product. If the electric cable is damaged,
it must be replaced by a qualified electri-
cian. Otherwise there is an electric shock,
short circuit or fire hazard!
• The mains supply data must correspond
to the data specified on the type label of
the product. The rating plate is either
seen when the door or the lower cover of
the appliance is opened or it is located at
the rear wall of the appliance depending
on the appliance type.
• Power cable plug must be within easy
reach after installation (do not route it
above the hob). Do not use extension or
multi sockets in power connection.
• and must use the appropriate socket out-
let/line and plug for oven. In case of the
product's power limits are out of current
carrying capability of plug and socket
outlet/line, the product must be connec-
ted through fixed electrical installation
directly without using plug and socket
outlet/line.
• If the product will be connected directly
to the supply power: If it is not possible
to disconnect all poles in the supply
power, a disconnection unit with at least
3 mm contact clearance (fuses, line
safety switches, contactors) must be
connected and all the poles of this dis-
connection unit must be adjacent to (not
above) the product in accordance with
IEE directives. Failure to obey this in-
struction may cause operational prob-
lems and invalidate the product warranty.
• Additional protection by a residual cur-
rent circuit breaker is recommended.
If the product is produced with cable and
without plug:
Connect the cord of product to supply
power as identified below:
Make the terminal block connection of your
product according to the connection/phase
information on the product type label.
If your supply cord type is 3-conductor type,
for 1-phase connection:
- Brown/Black = L (Phase)
- Blue = N (Neutral)
- Green/Yellow wire = (E)
If your supply cord type is 5-conductor type,
for 3-phase connection:
- Brown = L1 (Phase)
EN / 22
EN
FR
(Earthing)