ONE
REGULAR INSTALLATION
REGULAR INSTALLATION
INSTALLATION RÉGULIÈRE
INSTALLATION RÉGULIÈRE
VEHICLE
VEHICULES
GENESIS
G90
Push-to-Start
IF THE VEHICLE IS NOT EQUIPPED WITH FUNCTIONAL HOOD PIN:
Program remote
Programmez l'option
démarreur à distance:
NOTES
The vehicles OEM remote and SmartKey are
still operable during remote start.
**
Parts required (Not included)
1X Fuse
3X 1Amp Diodes
2X 3Amp Diodes
MANDATORY INSTALL | INSTALLATION OBLIGATOIRE
HOOD STATUS : THE HOOD PIN SWITCH (INCLUDED)
* HOOD
MUST BE INSTALLED IF THE VEHICLE CAN BE
PIN
REMOTE STARTED WITH THE HOOD OPEN, SET FUNCTION A11 TO OFF.
CONTACT
STATUT DE CAPOT : LE CONTACT DE CAPOT (INCLUS), DOIT ÊTRE
DE CAPOT
INSTALLÉ SI LE VÉHICULE PEUT DÉMARRER À DISTANCE, LORSQUE LE
CAPOT EST OUVERT, PROGRAMMEZ LA FONCTION A11 À NON.
1 / 6
Page
Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule supportées dans
PUSH
START
YEARS
ANNÉES
2017-2020
BYPASS FIRMWARE VERSION
VERSION LOGICIELLE CONTOURNEMENT
[
76.
60
MINIMUM
Program bypass option:
Programmez l'option du contournement:
Program bypass option
(If equiped with OEM
Programmez l'option du contournement
(Si équipé d'une alarme
SI LE VÉHICULE N'EST PAS ÉQUIPÉ
D'UN CONTACT DE CAPOT FONCTIONNEL:
FUNCTION
FONCTION
starter option:
31
A11
REV.: 20240924
ce diagramme (fonctionnelles si équipé)
To add the firmware version and the options, use the
FLASH LINK UPDATER or FLASH LINK MOBILE tool,
]
UNIT OPTION
OPTION UNITE
C1
D6
alarm):
D2
d'origine):
A11
OFF
NON
MODE
DESCRIPTION
E1: (+) Parking Light - E2: Ign.2 - E5: Ign.1 - E6: (+) Start
5
E1: (+) Feux de stationnement - E2: Ign.2 - E5: Ign.1 - E6: (+)
Démarreur
La télécommande d'origine du véhicule et la clé intélligente reste
fonctionnel même si le démarreur est engagé.
Pièce(s) requise(s) (Non incluse(s))
1X Fusible
3X Diodes 1Amp
2X Diodes 3Amp
Notice: the installation of safety
elements are mandatory. The hood pin
SECURITY STICKER
OFF
and the sticker are essential security
NON
elements and must be installed.
AUTOCOLLANT DE
Notice: l'installation des éléments de
SÉCURITÉ
sécurité est obligatoire. Le contact de
WARNING
capot et l'autocollant de sécurité sont
ATTENTION
des éléments de sécurité essentiels et
Included
doivent absolument être installés.
Inclus
GUIDE # 94021
ADDENDUM - SUGGESTED WIRING CONFIGURATION
ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ
sold separately.
Pour ajouter la version logicielle et les options,
utilisez l'outil FLASH LINK UPDATER
ou FLASH LINK MOBILE, vendu séparément.
DESCRIPTION
OEM Remote status (Lock/Unlock)
monitoring
Suivi des status (Verrouillage/Déverrouil-
lage) de la télécommande d'origine
Push-to-Start
Push-to-Start
Unlock before / Lock after (Disarm OEM
alarm)
Déverrouille avant / Verrouille après
(Désarme l'alarme d'origine)
Hood trigger (Output Status).
Contact de capot (état de sortie).
THIS MODULE MUST BE INSTALLED BY A
QUALIFIED TECHNICIAN. A WRONG
CONNECTION CAN CAUSE PERMANENT
DAMAGE TO THE VEHICLE.
CE MODULE DOIT ÊTRE INSTALLÉ PAR
UN TECHNICIEN QUALIFIÉ, TOUTE
ERREUR DANS LES BRANCHEMENTS
PEUT OCCASIONNER DES DOMMAGES
PERMANENTS AU VÉHICULE.
loading

Sommaire des Matières pour Fortin 94021

  • Page 1 1 / 6 REV.: 20240924 GUIDE # 94021 Page REGULAR INSTALLATION REGULAR INSTALLATION ADDENDUM - SUGGESTED WIRING CONFIGURATION INSTALLATION RÉGULIÈRE INSTALLATION RÉGULIÈRE ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule supportées dans ce diagramme (fonctionnelles si équipé)
  • Page 2 This guide may change without notice. See www.fortin.ca for latest version. 2 / 6 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DESCRIPTION | DESCRIPTION Front of the fuse box Au devant de la boîte à fusibles...
  • Page 3 This guide may change without notice. See www.fortin.ca for latest version. 3 / 6 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. WIRING CONNECTION | GUIDE DE BRANCHEMENTS Yellow Purple Purple/White Green CUT LOOP FOR AUTOMATIC TRANSMISSION MODE.
  • Page 4 4 / 6 Page Insert the 6-Pin Main connector. enfoncé: Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. Insérez le connecteur HOLD KEY BYPASS PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ...
  • Page 5 5 / 6 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. REMOTE STARTER PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION DU DÉMARREUR À DISTANCE REFER TO THE QUICK INSTALL GUIDE INCLUDED WITH THE MODULE FOR THE REMOTE STARTER PROGRAMMING.
  • Page 6 The installation in every case is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability or responsibility whatsoever resulting from any type of installation, whether performed properly, improperly or any other way.