REGULAR & THAR-FOR3 INSTALLATION
INSTALLATION RÉGULIÈRE ET THAR-FOR3
VEHICLE
VEHICULES
FORD
Explorer
Push-to-Start
MODEL: EVO-ONE
DATE:02/2019
FORTIN.CA
SN: 000000 00000
2019
MADE IN CANADA
© 2018 ALL RIGHTS RESERVED
IF THE VEHICLE IS NOT EQUIPPED WITH FUNCTIONAL HOOD PIN:
Program remote
starter option for
OEM REMOTE STAND
Programmez l'option
démarreur à distance
pour
TÉLÉCOMMANDE
D'ORIGINE STAND
NOTES
The vehicles OEM remote and SmartKey are
still operable during remote start.
The heated seats and rear defrost activate
**Heated seats
automatically when it's cold.
**Rear Defrost
The parking Lights at remote start only.
***Parking Lights
MANDATORY INSTALL | INSTALLATION OBLIGATOIRE
HOOD STATUS : THE HOOD PIN SWITCH (INCLUDED)
* HOOD
MUST BE INSTALLED IF THE VEHICLE CAN BE
PIN
REMOTE STARTED WITH THE HOOD OPEN, SET FUNCTION A11 TO OFF.
CONTACT
STATUT DE CAPOT : LE CONTACT DE CAPOT (INCLUS), DOIT ÊTRE
DE CAPOT
INSTALLÉ SI LE VÉHICULE PEUT DÉMARRER À DISTANCE, LORSQUE LE
CAPOT EST OUVERT, PROGRAMMEZ LA FONCTION A11 À NON.
1 / 9
Page
ONLY COMPATIBLE WITH AUTOMATIC TRANSMISSION VEHICLES.
COMPATIBLE AVEC VÉHICULE À TRANSMISSION AUTOMATIQUE SEULEMENT.
Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule sup-
PUSH
START
YEARS
ANNÉES
2020-2024
QR CODE
ON THE
COMPATIBLE
LABEL
MODULE
MANUFACTURED
REQUIRED:
AFTER: 2019
CODE QR
MODULE
SUR
L'ÉTIQUETTE
COMPATIBLE
REQUIS:
FABRIQUÉ APRÈS: 2019
Program bypass option:
Programmez l'option du contournement:
SI LE VÉHICULE N'EST PAS ÉQUIPÉ
D'UN CONTACT DE CAPOT FONCTIONNEL:
FUNCTION
FONCTION
R.S.
:
ALONE
38
:
ALONE
A11
REV.: 20241212
REV.: 20241212
portées dans ce diagramme (fonctionnelles si équipé)
To add the firmware version and the options, use the
FIRMWARE VERSION
FLASH LINK UPDATER or FLASH LINK MOBILE tool,
VERSION LOGICIELLE
58.[02]
MINIMUM
UNIT OPTION
OPTION UNITE
C1
D6
A11
OFF
NON
MODE
DESCRIPTION
Enable
Press 3x Lock to remote start with the OEM remote.
2
Activé
Appuyez x3 sur Verrouille de la télécommance d'origine
pour démarrer à distance le véhicule.
La télécommande d'origine du véhicule et la clé intélligente reste
fonctionnel même si le démarreur est engagé.
Les sièges chauffants et le dégivrage arrière s'activent
automatiquement lorsqu'il fait froid.
Les feux de stationnement s'activent au démarrage à distance
seulement.
Notice: the installation of safety
elements are mandatory. The hood pin
SECURITY STICKER
OFF
and the sticker are essential security
NON
elements and must be installed.
AUTOCOLLANT DE
Notice: l'installation des éléments de
SÉCURITÉ
sécurité est obligatoire. Le contact de
WARNING
capot et l'autocollant de sécurité sont
ATTENTION
des éléments de sécurité essentiels et
Included
doivent absolument être installés.
Inclus
Guide # 96361
ADDENDUM - SUGGESTED WIRING CONFIGURATION
ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ
sold separately.
Pour ajouter la version logicielle et les options,
utilisez l'outil FLASH LINK UPDATER
ou FLASH LINK MOBILE, vendu séparément.
DESCRIPTION
OEM Remote status (Lock/Unlock)
monitoring
Suivi des status (Verrouillage/Déverrouil-
lage) de la télécommande d'origine
Push-to-Start
Push-to-Start
Hood trigger (Output Status).
Contact de capot (état de sortie).
THIS MODULE MUST BE INSTALLED BY A
QUALIFIED TECHNICIAN. A WRONG
CONNECTION CAN CAUSE PERMANENT
DAMAGE TO THE VEHICLE.
CE MODULE DOIT ÊTRE INSTALLÉ PAR
UN TECHNICIEN QUALIFIÉ, TOUTE
ERREUR DANS LES BRANCHEMENTS
PEUT OCCASIONNER DES DOMMAGES
PERMANENTS AU VÉHICULE.
loading

Sommaire des Matières pour Fortin 96361

  • Page 1 1 / 9 REV.: 20241212 REV.: 20241212 Guide # 96361 Page REGULAR & THAR-FOR3 INSTALLATION ADDENDUM - SUGGESTED WIRING CONFIGURATION ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ INSTALLATION RÉGULIÈRE ET THAR-FOR3 ONLY COMPATIBLE WITH AUTOMATIC TRANSMISSION VEHICLES. COMPATIBLE AVEC VÉHICULE À TRANSMISSION AUTOMATIQUE SEULEMENT.
  • Page 2 This guide may change without notice. See www.fortin.ca for latest version. 2 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. NOTES THE REMOTE START WILL NOT OPERATE IF : LE DÉMARREUR NE FONCTIONNERA PAS SI :...
  • Page 3 This guide may change without notice. See www.fortin.ca for latest version. 3 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DESCRIPTION | DESCRIPTION Parts required (Not Pièce(s) requise(s) (Non PAGE...
  • Page 4 This guide may change without notice. See www.fortin.ca for latest version. Guide # 96361 4 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. AUTOMATIC TRANSMISSION WIRING CONNECTION | SCHÉMA DE BRANCHEMENT TRANSMISSION AUTOMATIQUE Yellow Purple...
  • Page 5 This guide may change without notice. See www.fortin.ca for latest version. Guide # 96361 5 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. THAR-FOR3 | T-HARNESS - AUTOMATIC TRANSMISSION | T-HARNAIS - TRANSMISSION AUTOMATIQUE Yellow Purple...
  • Page 6 This guide may change without notice. See www.fortin.ca for latest version. 6 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DCRYPTOR PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION AVEC DCRYPTOR Parts required (not included) Pièces requises (non incluses)
  • Page 7 This guide may change without notice. See www.fortin.ca for latest version. 7 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. KEY BYPASS PROGRAMMING PROCEDURE 2/2 | PROCÉDURE DE PROGRAMMATION CONTOURNEMENT DE CLÉ 2/2 IGNITION OFF...
  • Page 8 8 / 9 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. REMOTE STARTER PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION DU DÉMARREUR À DISTANCE REFER TO THE QUICK INSTALL GUIDE INCLUDED WITH THE MODULE FOR THE REMOTE STARTER PROGRAMMING.
  • Page 9 The installation in every case is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability or responsibility whatsoever resulting from any type of installation, whether performed properly, improperly or any other way.