RINSE INJECTOR AFTER EACH USE
Additive allowed to remain in injector can dry, foul or damage the lower end at the next start-up. Place suction tube into a
0.95 liters (1 qt.) or more container of fresh filtered water. Flow fresh water through the injector by operating until container is
empty. This procedure is not needed for continuous operation.
CLEAN SOLUTION CONTAINER
Keep covered to prevent dirt, flies and other debris from entering the container. Rinse container thoroughly and often. Do not
mix chemicals together that might react and cause a precipitate. Use FILTERED fluid when filling container.
CLEAN SUCTION TUBE FILTER SCREEN
Inspect each time new solution is added. Clean filter screen (#27) and suction tube (#25) as necessary by rinsing in fresh
water. Replace if necessary. Keep filter screen off bottom of solution container to prevent dirt and precipitate from clogging
filter.
CLEAN INLET FILTER
Clean or replace inlet filter as required to increase the life of the unit as well as reduce pressure loss.
BYPASS INJECTOR
When not in use place the injector in bypass mode by using the three valve bypass.
STORAGE
For extended storage, rinse injector (see "Rinse Injector After Each Use") and place underwater in a container. Apply monthly,
<29 ml (0.1 oz.) of chlorine bleach to avoid algae growth. KEEP FROM FREEZING.
Refer to page 24
AQUAMIX S (0.3%) Model
Every 3 - 6
Every 6 - 12
Months
1. Clean seal areas
1. Replace #17 O-ring
(#51 & 13).
#51 Shaft Assembly.
2. Check #17 O-ring,
2. Clean and/or replace
#68 Cylinder, clean
#13 Check Poppet, #11
and/or replace as
Suction Tube Fitting, #68
necessary.
inner cylinder.
English: 20

Maintenance

Reference numbers refer to Page 23 - 26
Perform these maintenance
procedures to extend the life of your unit.
Replace as
months
necessary
1. #68 Cylinder
2. #51 Shaft
Assembly Dosage
Piston
Refer to page 25 & 26
AQUAMIX M (2.5%) , L (5%) Models
Every 3 - 6
Every 6 - 12
Months
months
1. Clean seal areas
1. Replace #17 O-ring
(#14 & 13).
and #44 Dosage Piston/
2. Check #17 O-ring,
gasket (WSP model).
#7 Cylinder, clean
2. #13 Check Poppet ,
and/or replace as
#11 Suction Tube Fitting.
necessary.
Replace as
necessary
1. #7 Cylinder
2. #14 O-ring