Ashley AG30LPC Manuel D'instructions Et D'utilisation Du Propriétaire
Ashley AG30LPC Manuel D'instructions Et D'utilisation Du Propriétaire

Ashley AG30LPC Manuel D'instructions Et D'utilisation Du Propriétaire

Les langues disponibles

Les langues disponibles

Owner's Instruction and Operation Manual
Model Number:
AG30LPC
Report # F18-149
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER'S AUTHORIZED REPRESENTATIVE,
IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER, PROVINCIAL OR TERRITORIAL
AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE
CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
If the information in these instructions is not followed exactly, a fire, explosion or productions of carbon
monoxide may result, causing property damage, personal injury, or loss of life. The qualified service agency
is responsible for proper installation of this kit. The installation is not proper and complete until operation
of the converted appliance is checked as specified in the manufacturer's instructions supplied with
the kit. Refer to appliance owner's manual or product data plate for proper inlet and manifold pressure
adjustments and orifice sizing.
READ ALL STEPS BEFORE STARTING INSTALLATION. LEAVE THESE INSTRUCTIONS WITH THE
This gas conversion kit installation instructions must be used in conjunction with the installation and
operation manual provided with the appliance. Please read the appliance owner's manual completely before
performing any procedures in these instructions. All warnings, precautions, and instructions outlined in the
manual provided with the appliance will continue to apply to these instructions.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
www.nficertified.org
This conversion kit is only to be used on
the AG30FP model fireplace
APPLIANCE.
We recommend that our gas
hearth products be installed
and serviced by profes-
sionals who are certified in
the U.S. by the National
Fireplace Institute® (NFI) as
NFI Gas Specialists.
854023-1804M
Ph. 800-750-2723
Table des Matières
loading

Sommaire des Matières pour Ashley AG30LPC

  • Page 1 U.S. by the National Fireplace Institute® (NFI) as Model Number: NFI Gas Specialists. www.nficertified.org AG30LPC This conversion kit is only to be used on the AG30FP model fireplace Report # F18-149 854023-1804M * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
  • Page 2 LP CONVERSION KIT 4. Replace the existing orifice cap. The following instructions are for converting a natural gas (NG) fireplace to a liquid propane (LP) 5. Replace with the LP orifice cap included with fireplace. this kit. Tighten the cap securely. The sizes are stamped on the orifices.
  • Page 3 LP CONVERSION KIT 2. Attach manometer using a 1/4” (6 mm) I.D. hose. Light pilot and burner. Check pressure to ensure it is between the minimum and maximum recommended pressure settings. 3. Turn off burner and pilot. 4. Disconnect hose and tighten the inlet (IN) pressure tap by turning screw clockwise.
  • Page 4 LP CONVERSION KIT TABLE 3 Manifold Pressure LP Gas Fuel Natural Gas Low - High Low - High Gas Supply Manifold 1.1” - 3.8” WC 2.9” - 11” WC Pressure Tap (.27 - .95 kPa) (.72 - 2.74 kPa) Burner Ports VERIFY OPERATION Light the pilot.
  • Page 5: Trousse De Conversion Au Pl

    TROUSSE DE CONVERSION AU PL TABLEAU 3 Pression d’admission Gaz PL Combustible Gaz naturel Approvisionnement Faible – Élevée Faible – Élevée en gaz 1,1 à 3,8 po CE 2,9 à 11 po CE Prise de pression (0,27 à 0,95 (0,72 à 2,74 d’admission (B) Orifices du kPa)
  • Page 6: Terminer La Conversion

    TROUSSE DE CONVERSION AU PL Desserrer la prise d’entrée de pression (IN) en tournant la vis dans le sens antihoraire. Voir (A). Fixer le manomètre à l’aide d’un tube de D.I. ¼ po (6 mm). Veilleuse et brûleur. Vérifier la pression pour assurer qu’elle se trouve entre le minimum et le maximum de pression recommandé.
  • Page 7 TROUSSE DE CONVERSION AU PL Les instructions suivantes ont pour but de remplacer un TABLEAU 1 foyer au gaz naturel (GN) en foyer au propane liquide (PL) Dimension de l'orifice du brûleur à des altitudes entre 0 et 4500 pi (1372 m) COMPOSANTS DE LA TROUSSE DE Dimension de l'orifice Combustible...
  • Page 8: Numéro De Modèle

    États-Unis par le National Fireplace Institute® (NFI) en tant que spécialistes NFI en gaz. Numéro De Modèle: www.nficertified.org AG30LPC Cette trousse de conversion doit être uniquement utilisée sur un modèle de foyer AG30FP Rapport no F18-149 * Toutes les images de ce manuel sont à des fins d’illustration uniquement. Le produit réel peut varier.

Table des Matières