Dometic G4-7 Installation/Fonctionnement/Entretien
Dometic G4-7 Installation/Fonctionnement/Entretien

Dometic G4-7 Installation/Fonctionnement/Entretien

Chauffe eau au propane liquide
DOMETIC
DOMETIC
CORPORATION
1120 North Main Street, Elkhart, IN 46516
PHONE:
1-866-869-3118
INTERNET:
WWW.EDOMETIC.COM
EMAIL: CUSTOMERSUPPORTCENTER@DOMETIC.COM
ENGLISH,
FRANCA'S
This water heater design has been certified by the Canadian
Standards
Association
for installation
water heater is not for use in marine applications.
SERVICE CALLS & QUESTIONS
Location and phone numbers of qualified Service Centers can
be found at our website http:/www.edometic.com
1-866-869-3118
to have
a Service
SAFETY
ALERT
Safety Symbols alerting you to potential personal safety hazards,
Obey all safety messages following these symbols.
WARNING
avoid possible
injury or death
Installation and service must be performedby a qualified Service
Technician, Service Center, OEM or Gas Supplier.
WARNING
FIRE
OR
• If the information
in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT
TO DO IF YOU
SMELL
• EvacuateALL persons from vehicle.
• Shut off gas supply at gas container or source.
• DONOT touch any electrical switch, or use any phone or
radio
in vehicle.
• DONOTstart vehicle's engine or electric generator.
• Contact nearest gas supplier or qualified Service Technician
for repairs.
• If you cannot reach a gas supplier or qualified Service
Technician, contact the nearest fire department.
• DONOTturn on gas supply until gas leak(s) has been
repaired.
Canada)
in recreation
vehicles.
This
or call
Center
List mailed.
SYMBOLS
CAUTION
avoid possible
injury and/or propeny damage
EXPLOSION
GAS
LITERATURE
c
US
•Installation
WATER HEATER
MODEL IDENTIFICATION ..... ......
DIMENSIONS
WEIGHT
.
SAFETY
Water Heater GENERAL INSTALLATION ..... ..... ..... .... ...
Wiring
Cutout Chart
Pressure- TemperatureReliefValve
Consumer SafetyWarnings ...............................
How to OperateYour Water Heater ..................................................3
Maintenance
and Care Instructions
Preventative Maintenance ............................
Winterizing(Flushing)Instructions .
Pressure-TemperatureReliefValve..
Flushing to Remove UnpleasantOdor ..........................
FIGURES 1-12
PART IDENTIFICATION
water Heater WARRANTY
EXPLANATION
OF MODEL NUMBER
G
c
H
6
AA-IO
- IF YOUR MODEL NUMBER IS NOT LISTED-
Older revision numbers may be 3, 4, 6, 7, 8 or g (__
Regardlessof your revision number the current instructions are still generally
applicableto your unit. If you have questions contact your dealer,an Dometic
Service Center or the Dometic Service Department.
MODEL
NUMBER
CLARIFICATION
4 GAL
Pilot Ignition
G4-7
GC6AA-8
ElectronicIgnition
GC6AA-10E
Pilot Reli
ht
Heat Exchan
e
Electronic
I nition
Combination Gas/EIectric
DIMENSIONS
ALL
MODEL
WIDTH
6 GALLON
12.5"
1 0 GALLON
15.5"
NUMBER MPD
93755
L.P. GAS
WATER
HEATER
4 - 6 - 10 GALLON
Models
4-E
•Operation
•Maintenance
Effective 09.22.17
.
..
.
.
..
...................16
(EXAMPLE)
E/P
Electronic Ignition or Pilot Relight
Revision(NUMBER)
HeatingElement(SCREW-IN
4-6-10
galloncapacity
Engine Heat Exchange
Combination
Gas and AC Electric
Gas (PROPANE)
6 GAL
10 GAL
G6A-7
GC6AA-8P
GIO-2
GH6-7
GI 0-2P
G6A-8E
GCH6A-10E
GIO-3E
GH6-8E
GC10A-4E
P IN MODEL # - SEEMODEL CLARIFICATION
ABOVE
H IN MODEL # - SEEMODEL CLARIFICATION
ABOVE
E IN MODEL # - SEEMODEL CLARIFICATION
ABOVE
C IN MODEL # - SEEMODEL CLARIFICATION
ABOVE
SHIPPING
6 GALLON
10 GALLON
& IO-E
4
......5
..
5
......6-7
............8
ORBOLT-ON)
GCIOA-2
GCIOA-2P
GCHIOA-4E
GHIO-3E
WT.
25 lbs
32 lbs
Table des Matières
loading

Sommaire des Matières pour Dometic G4-7

  • Page 1 Regardlessof your revision number the current instructions are still generally Do not store or use gasoline or other flammable vapors and applicableto your unit. If you have questions contact your dealer,an Dometic liquids in the vicinity of this or any other appliance.
  • Page 2 Flush Mount (MPD 93948) installations. Consult with your Field 4. Connect both 1/2" NPT water lines (FIG2) hot water outlet female Auditor, Account Manager, or the Dometic Service Department if you and cold water inlet female and 3/8" flared LP gas line to the water have additional questions.
  • Page 3 ANSI/NFPA70. FOR WHITE RODGERS' CONTROL (FIG7) a. Turn lighting control knob (7-B) to PILOT position and hold Your Dometic PILOT GASWATER HEATER is now ready for operation. against stop while lighting pilot burner. Continue to HOW TO OPERATE YOUR WATER HEATER b.
  • Page 4 OFF position for at least 30 seconds, then turn to ON position. • When water heater is not in use set temperature control lever (White 6, If a lockout condition persists contact an Dometic Service Center. Rogers) or dial (Robertshaw) to lowest possible position. This will Read MAINTENANCE AND CARE INSTRUCTIONS &...
  • Page 5 Dometic water heater tank is designed with an internal air gap at the top of the tank to reduce the possibility of dripping. In time, the that is very yellow.
  • Page 6 STRAIGHT SECTION VIEW Hot Water Outlet Cold Water Inlet From the Pump ROBERTSHAW WHITERODGERS...
  • Page 7: Wiring Diagrams

    TO ELEMENT RELAY GREEN GROUP BUCK USED 1 IOVHOT TO STUD DUAL SWITCH SINGLE SWITCH AS DOME71C DOMETIC BLUE FROM W.H. (LOCK-OUT LAMP) +12 VDC GAS- ORANGE FROM W.H. ELEC- WHITE FROM W.H. BLUE FROM W.H. JumperWire (LOCK-OUT LAMP) BATTERY...
  • Page 8: Part Identification

    PART IDENTIFICATION / IDENTIFICATION DES PILOT IGNITION / PILOT RELIGHT SPARK IGNITION / HEAT EXCHANGE ALLUMAGE DE VEILLEUSE / ALLUMAGE PAR ETINCELLES/ RALLUMAGE DE VEILLEUSE ÉCHANGE DECHALEUR GAZ- COMBIN AS/ELECTR!C LECTRICITE COM FOR IDENTIFICATION AND REPAIR PARTS CO TO: WWW.EDOMETICOCOM CHOOSE WATER HEATER...
  • Page 9 Sl VOUS SENTEZ DU GAZ généralement valablespourvotreunité.Pourtoutequestion,contactervotre • Evacuer TOUS Ies passagers du véhicule. distributeur, un centre de service Dometic ou le service ä Ia clientéle Dometic. • Couper Ilalimentation en gaz au niveau du réservoir ou å Ia source. EXPLICATION DU NUMÉRO...
  • Page 10: Installation Générale

    • Lorsqu'on utilise une connexion avec fil et fiche pour alimenter le chauffe-eau, Ie fil doit étre homologué LIL et convenir aux lieux AVERTISSEMENTS IMPORTANTS POUR LIINSTALLATION humides et aux usages intenses et super intenses. Le fil doit étre • Installer dans Ies véhicules de plaisance uniquement. Les véhicules souple, de type S, SO, ST, STO, SJ, SJT, SJTO, HS ou HSO, en de plaisance sont conqus comme résidences temporaires pour Ies conformité...
  • Page 11: Misesengardedestinées Au Consommateur

    • Installer Ia soupape dans l'ouverture prévue et marquée cet effet DÉCOUPE (FIG 1 ET2) sur le chauffe-eau. • L'installation doit étre conforme aux codes locaux ou, faute de CAPACITÉ DIMENSION D ELA DÉCOUPE PROFONDEUR codes locaux, å la norme américaine nationale pour véhicules de LITRES 15 - 22 32 cm...
  • Page 12 L'utilisation d'éléments de chauffe provenants de fabricants de marché secondaire pourra également entrainer des endommagements 1. Vérifier l'orifice du brüleur principal. des composantes ou du chauffe-eau. La garantie écrite Dometic 2. Nettoyer et régler le brüleur principal. stipule que la responsabilité d'un mauvais fonctionnement ou de 3.
  • Page 13: Pour Éliminer Lesmauvaises O Deurs

    5. Remplir Ie réservoir avec de I'eau fraiche ne contenant pas de souffre. Le chauffe-eau Dometic est conqu pour étre utilisé dans Ies véhicules de plaisance. Si vous utilisez votre véhicule fréquemment ou pour des périodes prolongées, rincer Ie chauffe-eau plusieurs fois par an...
  • Page 14 INTENTIONALLY LEFT BLANK...
  • Page 15 1. For a period of two years from the date of purchase, Dometic will Damage or failure resulting from misuse (including failure to seek proper replace the complete water heater if the inner tank leaks due to repair service), misapplication, alterations, water damage, or freezing are corrosion.

Table des Matières