A. Pressure Switch: - The pressure switch is the activation mechanism used to start and stop
the compressor. When the switch is pulled
out to the "On" position, the motor and pump
will compress air until tank pressure reaches
the upper limit of the factory set operating
pressure. When tank pressure falls below
the factory set "cut in" pressure, the
compressor will again automatically start to
compress air.
B. Tank Pressure Gauge: The tank pressure
gauge indicates the air pressure that is
present in the tank in PSI (lbs/sq. in.).
C. Regulated Pressure Gauge: The
regulated pressure gauge indicates the
amount of pressure allowed into the
discharge line (E) according to the setting of
the regulator.
D. Regulator Knob: The regulator knob is used to adjust the air pressure available at the
discharge line. The discharge air pressure is increased by turning the knob clockwise and
decreased by turning the knob counter clockwise.
E. Drain Valve: Twist style valve that drains moisture from the tank when opened.

OPERATION INSTRUCTIONS

FEATURES OF THE HAUSSMANN C60P
C
D
E
16
Pre-Start Procedures:
1. Inspect the compressor for any damaged components. Do not operate if compressor is
damaged.
2. Verify that the tanks have been drained and are clear of any moisture or dirt (See
"Draining Tank" below).
Start-Up Procedures:
1. Verify that the On/Off switch is in the Off position.
B
2. Verify that the tank air pressure is at 0 PSI.
3. Attach the air hose to the discharge line.
4. Plug the unit into a properly grounded outlet.
A
5. Pull out the On/Off switch to On. The compressor will automatically cycle on and off to
keep the tank pressure maintained .
6. Adjust the pressure regulator to the proper pressure setting required for the air tool.
Shut-Off Procedures:
1. Push in the On/Off switch to the Off position.

GENERAL MAINTENANCE

Service and Maintenance:
Prior to performing service and maintenance to the compressor, always disconnect all
accessories and attachments from the unit, and disconnect the compressor from the
electrical source. When replacing parts, only use Genuine HAUSSMANN replacement parts.
Notice!: This compressor is equipped with an oil-free pump. There is no oil to replace or
check.
Draining Tank - Twist-Style Drain Valve:
1. Verify that the compressor is turned Off.
2. Holding the handle, tilt the compressor toward the drain valve so it is positioned
at the bottom of the tank.
3. Turn the drain valve to open.
4. Keep the compressor tilted until all moisture has been removed.
ANY OTHER SERVICE SHOULD ONLY BE PERFORMED BY AN AUTHORIZED

TROUBLESHOOTING GUIDE